{"id":10176,"date":"2017-12-27T15:59:18","date_gmt":"2017-12-27T20:59:18","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=126"},"modified":"2026-10-22T14:52:19","modified_gmt":"2026-10-22T18:52:19","slug":"motor-bearings-electrical-damage-simplified-examination-clarification","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/","title":{"rendered":"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The article below corrects and adds to the EASA Current&#8217;s article from the Dec 2017 issue:\u00a0 \u201cMotor bearings: Electrical damage simplified.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An article on electrical bearing damage recently appeared in EASA Currents Magazine. While it raised a lot of good points, it also contained information on shaft grounding practices and shaft grounding rings which need correction or further examination. As we discuss electrical bearing damage, please note that we are referring to motors operated by variable frequency drives (VFD).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The title of the article was \u201cMotor bearings: Electrical damage simplified.\u201d True to this title, the article tries to stay as \u201cnontechnical\u201d as possible. Unfortunately, staying \u201cnontechnical\u201d is not always desirable since a thorough understanding of bearing currents and solutions is critical for successful repairs.\u00a0 As the inventors of conductive microfiber shaft grounding rings \u2013 the AEGIS<sup>\u00ae<\/sup> products &#8211; we\u2019ve been discussing electrical bearing damage and its solution for over twelve years. It is my opinion that in trying to keep it simple, the article sometimes oversimplifies the problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When talking about shaft grounding, it is a mistake not to differentiate capacitive shaft voltage discharge currents (EDM currents) and circulating currents (be they low or high frequency). The author states that his preferred method of bearing protection is to \u201cbreak the electrical circuit on the opposite drive end (ODE)\u201d of the motor, and install shaft grounding at the drive side. <img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" alt=\"Total_Qualitative_Bearing_Currents630px\" height=\"316\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px.jpg\" width=\"325\">This mirrors our recommended approach for AC motors over 100 HP and for all medium voltage motors. However, circulating currents are not an issue in small AC motors (under 100 HP), so bearing insulation is unnecessary for them and adding a shaft grounding ring to the DE or NDE is sufficient to protect the motor\u2019s bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But the author then states that \u201cif the [shaft] voltage can be clamped low enough with just a grounding brush, the ODE insulation is not always necessary.\u201d This is false. Shaft grounding cannot prevent circulating currents. So, 100 HP+ and medium voltage motors would still be at risk of circulating currents. These motors will always need both shaft grounding (preferably the drive end), and some type of insulation at the opposite end (preferably the ODE).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is another confusing or confused statement about circulating currents in the same paragraph: \u201cThis looping is also the reason [not to] install shaft grounding on the ODE as the loop can extend into the driven machine\u201d and thereby damage its bearings. This is easily misconstrued to mean that shaft grounding should never be installed at the ODE. But it is important to know that this applies only when circulating currents are a potential problem, i.e. motor over 100 HP and medium voltage motors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When discussing circulating currents potentially extending \u201cinto the driven machine\u201d we advise referring to the IEEE 112 which recommends insulating the NDE to avoid a circulating current path in the driven machine. Last but certainly not least, it is important to remember that installing a shaft grounding ring on the DE is still necessary to prevent capacitive voltages from causing EDM damage to the steel (non-insulated) bearing and\/or going down the shaft to the driven equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"Motors_100HP_or-Less630px\" height=\"203\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Motors_100HP_or-Less630px.jpg\" width=\"300\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Motor under 100 HP only needs a shaft grounding ring to protect the bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"Motors_More-than_100HP630px\" height=\"222\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Motors_More-than_100HP630px.jpg\" width=\"300\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Motor over 100 HP and need insulation (NDE) with a shaft grounding ring on the opposite end (DE)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now for a discussion on shaft voltages: The author gives a maximum safe shaft voltage level of 5 V peak to peak, and correctly points out that there is no universally applicable \u201csafe\u201d level of shaft voltage. In fact, it the peak voltages which harm the bearings so discussing \u201cpeak\u201d voltage is key. The NEMA MG1 document gives a range of 10 to 40 volts peak (20 to 80 volts peak to peak) as the shaft voltage level where bearing discharge can occur. But every system is different; every motor in every state of operation will have its own bearing breakdown voltage where discharge through the bearing occurs. With the lack of a consistent safe level across systems, neither peak voltage nor peak-to-peak measurements are a reliable measure of risk.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Therefore, we recommend that machine owners or motor repair technicians take shaft voltage readings with a high-speed oscilloscope (at least 100 MHz bandwidth). With this equipment, you can unambiguously tell whether discharge is occurring in the bearings. The smoking gun is a discharge pattern in the shaft voltage waveform (a slow voltage buildup followed by a rapid transition down).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/High-Amp-Discharge-Pattern630px-e1590606722596.jpg\" alt=\"High-Amp-Discharge-Pattern630px-e1590606722596\" style=\"width:325px\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">While the article recommends shaft voltage testing, it only recommends measuring peak-to-peak voltage, even though it is not the most important measure. The sample shaft voltage reading in the article has a timescale of 2 ms\/div, which is far too long to detect discharges, which occur on a timescale of microseconds. More on this in the <a href=\"https:\/\/www.est-aegis.com\/resources\/handbook\/\" rel=\"noopener\" target=\"_blank\">Bearing Protection Handbook<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The shaft grounding ring section starts off well, but goes awry in the second sentence by referring to \u201cthe standard single row ring.\u201d This refers to the AEGIS<sup>\u00ae<\/sup> SGR, for low voltage motors, but SGRs have two rows of conductive microfibers, not one. Next the article states that the standard SGRs are \u201cusually\u201d sufficient for smaller motors, but \u201cmay not always provide a low enough resistance circuit [<em>sic<\/em>] to ground.\u201d An SGR with two fiber rows is extremely effective and is proven in millions of applications worldwide on low voltage motors under 500 HP (and as noted earlier, motors over 100 HP also need bearing insulation in addition to the SGR ring).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The article does better when talking about the six fiber-row AEGIS<sup>\u00ae<\/sup> PRO Rings, saying \u201cThese rings are the best option for the least amount of maintenance.\u201d AEGIS<sup>\u00ae<\/sup> PRO rings are in fact the best and recommended option for medium voltage motors and LV motors over 500 HP.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The author does seem confused, though, about the purpose of the extra rows of conductive microfibers in the PRO ring. He seems to think the extra rows are to decrease the PRO\u2019s resistance relative to an SGR. But in fact, the extra rows serve to increase current carrying capacity, not resistance\/impedance per se. This extra capacity is needed for medium voltage and large low voltage motors (500 HP+) because they have higher shaft currents and the PRO ring\u2019s extra rows accommodate that increased current.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The article later claims that \u201cthey can be susceptible to wear, heat, and grease contamination.\u201d It is unclear whether \u201cthey\u201d refers to PRO rings or SGRs, but the claim is inaccurate for either product. Any properly installed AEGIS<sup>\u00ae<\/sup> ring is not susceptible to wear. It is designed as a \u201cwear-to-fit\u201d device; the fibers slowly wear until they just-touch the shaft surface, a process which can take 200,000 hours or more. Electrical contact is maintained, by physical contact and near-contact electron transfer, so the ring does not stop working. As for heat tolerance, the manufacturer spec states that AEGIS<sup>\u00ae<\/sup> rings can withstand temperatures up to 410\u00b0 F (210\u00b0 C), and we know of at least one customer who uses AEGIS<sup>\u00ae<\/sup> rings in an oven at 400 degrees.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As for grease, the AEGIS<sup>\u00ae<\/sup> fibers cut through and tolerate light grease, but this is a moot point. As the article mentions, AEGIS<sup>\u00ae<\/sup> rings can be mounted inside motors, away from external grease and grime, and this is where motor repair shops should install them. One bit of information the article left out is that there is even a UL-approved process for installing AEGIS<sup>\u00ae<\/sup> rings inside explosion proof motors, which is unique among shaft grounding technologies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now we come to the author\u2019s preferred shaft grounding method, the copper bristle brush. These devices have a few shortcomings that went unmentioned. The brush\u2019s springs may clog and jam, copper is easily oxidized to its nonconductive green\/blue oxide, and the shaft can glaze. Also, we are rather skeptical about the use of grease on the brush.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The article only mentions common mode chokes (CMC) briefly, but manages to get a few errors into those three sentences. The most important one to correct is the misleading statement that they \u201cdo not always reduce the shaft voltage to a low enough level to eliminate bearing damage.\u201d In fact, common mode chokes barely affect shaft voltage at all and do nothing to eliminate EDM bearing discharges from the capacitive induced shaft voltage. CMCs are just not useful against the shaft voltage discharge currents that shaft grounding protects against. They may be able to reduce high-frequency circulating currents, but CMCs are not as effective as insulating one bearing, as described above. At any rate, common mode chokes cannot take the place of shaft grounding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">All that said, the article ends with some good preventive maintenance advice, including making regular shaft voltage measurements, and advising specifying engineers to call for motors with preventive measures installed. It ends, \u201cGood service centers will identify electrically damaged bearings and strive to recommend the best method to prevent further issues.\u201d We agree wholeheartedly. Bearing inspection is required by the ANSI\/EASA Standard AR100-2015, and by the EASA warranty checklist, and is also one of the processes required of accredited EASA motor repair shops.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ultimately, this article was written to educate motor repair shops and more importantly, to help them improve their processes and so improve their business. We agree with these goals and hope that the original article succeeds in encouraging an enlightened discussion and seeking the most accurate information when considering bearing protection. And we hope that this article, too, will help advance those goals.<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Motor bearings: Electrical damage simplified &#8211; A further examination and clarification<\/p>\n","protected":false},"author":7,"featured_media":9075,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1065],"tags":[],"class_list":["post-10176","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bearing-damage-basics"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Motor bearings: Electrical damage simplified - A further examination and clarification\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Motor Bearings: Electrical Damage Simplified - A Further Examination\" \/>\n\t\t<meta property=\"og:description\" content=\"Motor bearings: Electrical damage simplified - A further examination and clarification\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"292\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2017-12-27T20:59:18+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T18:52:19+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Motor Bearings: Electrical Damage Simplified - A Further Examination\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Motor bearings: Electrical damage simplified - A further examination and clarification\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesedauer\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"8 Minuten\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#article\",\"name\":\"Motor Bearings: Electrical Damage Simplified - A Further Examination\",\"headline\":\"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg\",\"width\":300,\"height\":292,\"caption\":\"#image_title\"},\"datePublished\":\"2017-12-27T15:59:18-05:00\",\"dateModified\":\"2026-10-22T14:52:19-04:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#webpage\"},\"articleSection\":\"Bearing Damage Basics, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"name\":\"Bearing Damage Basics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"position\":2,\"name\":\"Bearing Damage Basics\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/bearing-damage-basics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#listItem\",\"name\":\"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#listItem\",\"position\":3,\"name\":\"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"name\":\"Bearing Damage Basics\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/\",\"name\":\"Motor Bearings: Electrical Damage Simplified - A Further Examination\",\"description\":\"Motor bearings: Electrical damage simplified - A further examination and clarification\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#mainImage\",\"width\":300,\"height\":292,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-bearings-electrical-damage-simplified-examination-clarification\\\/#mainImage\"},\"datePublished\":\"2017-12-27T15:59:18-05:00\",\"dateModified\":\"2026-10-22T14:52:19-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Motor Bearings: Electrical Damage Simplified - A Further Examination<\/title>\n\n","aioseo_head_json":{"title":"Motor Bearings: Electrical Damage Simplified - A Further Examination","description":"Motor bearings: Electrical damage simplified - A further examination and clarification","canonical_url":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#article","name":"Motor Bearings: Electrical Damage Simplified - A Further Examination","headline":"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification","author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg","width":300,"height":292,"caption":"#image_title"},"datePublished":"2017-12-27T15:59:18-05:00","dateModified":"2026-10-22T14:52:19-04:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#webpage"},"articleSection":"Bearing Damage Basics, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/bearing-damage-basics\/#listItem","name":"Bearing Damage Basics"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/bearing-damage-basics\/#listItem","position":2,"name":"Bearing Damage Basics","item":"https:\/\/www.est-aegis.com\/de\/blog\/category\/bearing-damage-basics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#listItem","name":"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#listItem","position":3,"name":"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/bearing-damage-basics\/#listItem","name":"Bearing Damage Basics"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/de\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/de\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/de\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#webpage","url":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/","name":"Motor Bearings: Electrical Damage Simplified - A Further Examination","description":"Motor bearings: Electrical damage simplified - A further examination and clarification","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#mainImage","width":300,"height":292,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/#mainImage"},"datePublished":"2017-12-27T15:59:18-05:00","dateModified":"2026-10-22T14:52:19-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/de\/#website","url":"https:\/\/www.est-aegis.com\/de\/","name":"Electro Static Technology","inLanguage":"de-DE","publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Motor Bearings: Electrical Damage Simplified - A Further Examination","og:description":"Motor bearings: Electrical damage simplified - A further examination and clarification","og:url":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg","og:image:width":300,"og:image:height":292,"article:published_time":"2017-12-27T20:59:18+00:00","article:modified_time":"2026-10-22T18:52:19+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Motor Bearings: Electrical Damage Simplified - A Further Examination","twitter:description":"Motor bearings: Electrical damage simplified - A further examination and clarification","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg","twitter:label1":"Verfasst von","twitter:data1":"AEGIS","twitter:label2":"Gesch\u00e4tzte Lesedauer","twitter:data2":"8 Minuten"},"aioseo_meta_data":{"post_id":"10176","title":"Motor Bearings: Electrical Damage Simplified - A Further Examination","description":"Motor bearings: Electrical damage simplified - A further examination and clarification","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-22 19:46:02","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:14:00","updated":"2026-11-16 21:28:52","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/blog\/category\/bearing-damage-basics\/\" title=\"Bearing Damage Basics\">Bearing Damage Basics<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tMotor Bearings: Electrical Damage Simplified \u2013 A Further Examination and Clarification\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/de\/"},{"label":"Bearing Damage Basics","link":"https:\/\/www.est-aegis.com\/de\/blog\/category\/bearing-damage-basics\/"},{"label":"Motor Bearings: Electrical Damage Simplified &#8211; A Further Examination and Clarification","link":"https:\/\/www.est-aegis.com\/de\/blog\/motor-bearings-electrical-damage-simplified-examination-clarification\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-300x292-3.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/10176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/comments?post=10176"}],"version-history":[{"count":2,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/10176\/revisions"}],"predecessor-version":[{"id":10608,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/10176\/revisions\/10608"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media\/9075"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media?parent=10176"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/categories?post=10176"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/tags?post=10176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}