{"id":127,"date":"2018-05-23T14:35:20","date_gmt":"2018-05-23T18:35:20","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=127"},"modified":"2026-11-05T10:05:30","modified_gmt":"2026-11-05T15:05:30","slug":"motor-repair-best-practices-for-vfd-driven-motors","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/","title":{"rendered":"Motor Repair Best Practices for VFD-Driven Motors"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the result is costly down time and production interruptions. Avoiding these costs makes economic sense and pays a high return on investment.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><a href=\"https:\/\/www.est-aegis.com\/markets\/motor-repair.php\" linktext=\"\" rel=\"noopener\">VFD-Driven Motors Can Fail From Destructive Bearing Currents &#8211; Costing Downtime and Lost Production<\/a><\/h3>\n\n\n\n<p><a href=\"https:\/\/www.est-aegis.com\/markets\/motor-repair.php\" rel=\"noopener\">\n<p><img loading=\"lazy\" decoding=\"async\" alt=\"ANSI\/EASA Standard AR100-2015\" class=\"aligncenter size-full wp-image-1504\" height=\"112\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png\" width=\"700\"><\/p>\n<img loading=\"lazy\" decoding=\"async\" alt=\"Motor Repair Best Practices\" class=\"alignleft wp-image-1494 size-large\" height=\"1024\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Motor-repair_Page_1-2-308x1024-1.jpg\" width=\"308\"><\/a>VFDs induce destructive shaft voltages and high-frequency currents which will cause electrical discharge machining (EDM) pitting, fusion craters, and fluting damage to the motor\u2019s bearings and deteriorate the bearing lubrication by allowing electrical arcing to burn the grease.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Cost Avoidance &#8211; Follow Best Practices to Ensure Up-time and Reliability<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Motor repair best practices will provide bearing protection from these destructive bearing currents by adding AEGIS<sup>\u00ae<\/sup> Shaft Grounding Ring Technology and, when needed, insulating a bearing to prevent high frequency circulating currents.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Motors up to 100 HP &#8211; Add AEGIS Shaft Grounding Ring to discharge shaft voltages to ground.<\/li>\n\n\n<li>Motors over 100 HP &#8211; Add AEGIS Ring at one end and insulate the bearing at the opposite end.<\/li>\n\n\n<li>Detailed recommendations are contained in the <a href=\"https:\/\/www.est-aegis.com\/resources\/handbook\/\" rel=\"noopener\" target=\"_blank\">AEGIS Bearing Protection Handbook<\/a>.<\/li>\n\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Motor Bearings are the Most Vulnerable Parts and the Cost of a Failed Motor Adds Up Quickly<\/h4>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright is-resized\"><img decoding=\"async\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Motor-repair_Page_1-3-300x162-1.jpg\" alt=\"Failed motor costs\" style=\"width:300px;height:162px\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">The return on investment in repairing motors and following the AEGIS Bearing Protection Handbook\u2019s best practices recommendations will pay dividends day after day and ensure the most reliable repair to the motor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re<\/p>\n","protected":false},"author":7,"featured_media":8977,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1069],"tags":[],"class_list":["post-127","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cost-and-reliability"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"What are Motor Repair Best Practices for VFD-Driven Motors\" \/>\n\t\t<meta property=\"og:description\" content=\"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t\t<meta property=\"og:image:height\" content=\"112\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2018-05-23T18:35:20+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-05T15:05:30+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"What are Motor Repair Best Practices for VFD-Driven Motors\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesedauer\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"2 Minuten\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#article\",\"name\":\"What are Motor Repair Best Practices for VFD-Driven Motors\",\"headline\":\"Motor Repair Best Practices for VFD-Driven Motors\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Picture1-e1527100456420.png\",\"width\":700,\"height\":112,\"caption\":\"#image_title\"},\"datePublished\":\"2018-05-23T14:35:20-04:00\",\"dateModified\":\"2026-11-05T10:05:30-05:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#webpage\"},\"articleSection\":\"Cost &amp; Reliability, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/cost-and-reliability\\\/#listItem\",\"name\":\"Cost &amp; Reliability\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/cost-and-reliability\\\/#listItem\",\"position\":2,\"name\":\"Cost &amp; Reliability\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/cost-and-reliability\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#listItem\",\"name\":\"Motor Repair Best Practices for VFD-Driven Motors\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#listItem\",\"position\":3,\"name\":\"Motor Repair Best Practices for VFD-Driven Motors\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/cost-and-reliability\\\/#listItem\",\"name\":\"Cost &amp; Reliability\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/\",\"name\":\"What are Motor Repair Best Practices for VFD-Driven Motors\",\"description\":\"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \\u2013 sometimes within only weeks or months \\u2013 and the re\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Picture1-e1527100456420.png\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#mainImage\",\"width\":700,\"height\":112,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/motor-repair-best-practices-for-vfd-driven-motors\\\/#mainImage\"},\"datePublished\":\"2018-05-23T14:35:20-04:00\",\"dateModified\":\"2026-11-05T10:05:30-05:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>What are Motor Repair Best Practices for VFD-Driven Motors<\/title>\n\n","aioseo_head_json":{"title":"What are Motor Repair Best Practices for VFD-Driven Motors","description":"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re","canonical_url":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#article","name":"What are Motor Repair Best Practices for VFD-Driven Motors","headline":"Motor Repair Best Practices for VFD-Driven Motors","author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png","width":700,"height":112,"caption":"#image_title"},"datePublished":"2018-05-23T14:35:20-04:00","dateModified":"2026-11-05T10:05:30-05:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#webpage"},"articleSection":"Cost &amp; Reliability, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/cost-and-reliability\/#listItem","name":"Cost &amp; Reliability"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/cost-and-reliability\/#listItem","position":2,"name":"Cost &amp; Reliability","item":"https:\/\/www.est-aegis.com\/de\/blog\/category\/cost-and-reliability\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#listItem","name":"Motor Repair Best Practices for VFD-Driven Motors"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#listItem","position":3,"name":"Motor Repair Best Practices for VFD-Driven Motors","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/cost-and-reliability\/#listItem","name":"Cost &amp; Reliability"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/de\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/de\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/de\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#webpage","url":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/","name":"What are Motor Repair Best Practices for VFD-Driven Motors","description":"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png","@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#mainImage","width":700,"height":112,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/#mainImage"},"datePublished":"2018-05-23T14:35:20-04:00","dateModified":"2026-11-05T10:05:30-05:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/de\/#website","url":"https:\/\/www.est-aegis.com\/de\/","name":"Electro Static Technology","inLanguage":"de-DE","publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"Electro Static Technology","og:type":"article","og:title":"What are Motor Repair Best Practices for VFD-Driven Motors","og:description":"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re","og:url":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png","og:image:width":700,"og:image:height":112,"article:published_time":"2018-05-23T18:35:20+00:00","article:modified_time":"2026-11-05T15:05:30+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"What are Motor Repair Best Practices for VFD-Driven Motors","twitter:description":"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png","twitter:label1":"Verfasst von","twitter:data1":"AEGIS","twitter:label2":"Gesch\u00e4tzte Lesedauer","twitter:data2":"2 Minuten"},"aioseo_meta_data":{"post_id":"127","title":"What are Motor Repair Best Practices for VFD-Driven Motors","description":"Motors operated by variable frequency drives (VFD) are vulnerable to premature bearing failure from VFD induced shaft voltages and bearing currents \u2013 sometimes within only weeks or months \u2013 and the re","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-05 15:07:55","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:14:01","updated":"2026-11-16 20:24:53","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/blog\/category\/cost-and-reliability\/\" title=\"Cost &amp; Reliability\">Cost &amp; Reliability<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tMotor Repair Best Practices for VFD-Driven Motors\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/de\/"},{"label":"Cost &amp; Reliability","link":"https:\/\/www.est-aegis.com\/de\/blog\/category\/cost-and-reliability\/"},{"label":"Motor Repair Best Practices for VFD-Driven Motors","link":"https:\/\/www.est-aegis.com\/de\/blog\/motor-repair-best-practices-for-vfd-driven-motors\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Picture1-e1527100456420.png","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/127","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/comments?post=127"}],"version-history":[{"count":4,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/127\/revisions"}],"predecessor-version":[{"id":10796,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/127\/revisions\/10796"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media\/8977"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media?parent=127"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/categories?post=127"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/tags?post=127"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}