{"id":63,"date":"2021-12-01T13:16:11","date_gmt":"2021-12-01T18:16:11","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=63"},"modified":"2026-10-22T15:01:00","modified_gmt":"2026-10-22T19:01:00","slug":"electrical-bearing-protection-qa-part-18","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A &#8211; Part 18"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 18 in a series of questions and answers from our Q&amp;A <strong><a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">webinars<\/a><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1. How are AEGIS Rings applied to submersible pump motors?<img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"alignright size-medium wp-image-3462\" height=\"178\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg\" width=\"300\"><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1.<\/strong> It depends on the manufacturer and motor.\u00a0 Some motor designs have the bearings in an oil bath.\u00a0 That&#8217;s a problem for now.\u00a0 We are developing grounding rings that can tolerate higher grease and oil levels.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But for now, you want any AEGIS ring to be running in a dry environment.\u00a0 We have grounding rings in plenty of submersible pumps.\u00a0 Just not in the oil-filled design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2. What value of shaft voltage could be acceptable?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2.<\/strong> We usually see zero to 35 V before shaft grounding.\u00a0 Say it&#8217;s 15 V.\u00a0 Then you put on an AEGIS ring, add a braided grounding strap, and put colloidal silver on the shaft.\u00a0 The shaft voltage will usually decrease to under 1 V peak.\u00a0 This is about as safe as it gets, so we use one volt as a benchmark.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But we can&#8217;t always get the shaft voltage so low.\u00a0 What you&#8217;re most looking for is a big reduction.\u00a0 We had a situation recently with a shaft with 45-50 V on it.\u00a0 Our best practices brought it down to 3 V.\u00a0 So you may not get shaft voltage down to zero, and it may not be perfect.\u00a0 But decreased shaft voltage will improve things, and we&#8217;ll work with you on whatever you&#8217;ve got.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3. You&#8217;ve said motors over 100 hp\/75 kW need, along with AEGIS, an insulated bearing.\u00a0 But those are expensive and difficult to install.\u00a0 Can you just use two AEGIS rings instead, one at each end of the motor?<img decoding=\"async\" alt=\"\" class=\"alignright size-medium wp-image-3018\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-300x300-1.jpeg\" width=\"230\"><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3.<\/strong> You don&#8217;t want to do that.\u00a0 That seems like a good idea, and we actually used to recommend two AEGIS rings.\u00a0 The logic was that the rings would offer much less resistance than the (ordinary) bearings, so the circulating current would only move through the rings.\u00a0 But we quickly found that it doesn&#8217;t work as planned; current still circulated through the bearings.\u00a0 Which is surprising but true.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">One insulated bearing opposite the AEGIS ring seems necessary to stop the circulating current.\u00a0 Lots of motor manufacturers are now installing insulated bearings at the non-drive end of larger motors.\u00a0 They do this with motors of 75 to 125 hp and up.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As for the expense:\u00a0 Yes, it&#8217;s expensive.\u00a0 But not as expensive as bearing failure.\u00a0 Say you&#8217;ve got a 200 hp motor, with one SGR, on a drive.\u00a0 The motor is protected against shaft voltage discharge but not circulating current.\u00a0 So a bearing may fail.\u00a0 If that happens, it&#8217;ll cost $5,000 to repair it.\u00a0 Plus, you&#8217;ll need to ship it wherever for repair, <em>plus<\/em> you&#8217;ll have the cost of downtime.\u00a0 Add an insulated bearing costs a lot less than the repair and downtime, by far.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/est-aegis.com\/training\"><img decoding=\"async\" alt=\"\" class=\"alignleft wp-image-2150\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/webinar-icon-Dec-22-2021-03-25-23-31-PM.png\" width=\"88\"><\/a>To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Shaft grounding for submersible pumps, &#8222;safe&#8220; levels of shaft voltage, &#038; why not to put one grounding ring at each end of the motor.<\/p>\n","protected":false},"author":7,"featured_media":1035,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-63","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Shaft grounding for submersible pumps, &quot;safe&quot; levels of shaft voltage, &amp; why not to put one grounding ring at each end of the motor.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A - Part 18\" \/>\n\t\t<meta property=\"og:description\" content=\"Shaft grounding for submersible pumps, &quot;safe&quot; levels of shaft voltage, &amp; why not to put one grounding ring at each end of the motor.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"178\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-12-01T18:16:11+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:00+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A - Part 18\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Shaft grounding for submersible pumps, &quot;safe&quot; levels of shaft voltage, &amp; why not to put one grounding ring at each end of the motor.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesedauer\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 Minuten\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A - Part 18\",\"headline\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 18\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/3ph-openwell-submersible-300x178-1.jpg\",\"width\":300,\"height\":178,\"caption\":\"#image_title\"},\"datePublished\":\"2021-12-01T13:16:11-05:00\",\"dateModified\":\"2026-10-22T15:01:00-04:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Opcional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 18\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 18\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/\",\"name\":\"Electrical Bearing Protection Q&A - Part 18\",\"description\":\"Shaft grounding for submersible pumps, \\\"safe\\\" levels of shaft voltage, & why not to put one grounding ring at each end of the motor.\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/3ph-openwell-submersible-300x178-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#mainImage\",\"width\":300,\"height\":178,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-18\\\/#mainImage\"},\"datePublished\":\"2021-12-01T13:16:11-05:00\",\"dateModified\":\"2026-10-22T15:01:00-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A - Part 18<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A - Part 18","description":"Shaft grounding for submersible pumps, \"safe\" levels of shaft voltage, & why not to put one grounding ring at each end of the motor.","canonical_url":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#article","name":"Electrical Bearing Protection Q&A - Part 18","headline":"Electrical Bearing Protection Q&#038;A &#8211; Part 18","author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg","width":300,"height":178,"caption":"#image_title"},"datePublished":"2021-12-01T13:16:11-05:00","dateModified":"2026-10-22T15:01:00-04:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#webpage"},"articleSection":"Q&amp;A Series, Opcional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#listItem","name":"Electrical Bearing Protection Q&#038;A &#8211; Part 18"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A &#8211; Part 18","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/de\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/de\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/de\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#webpage","url":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/","name":"Electrical Bearing Protection Q&A - Part 18","description":"Shaft grounding for submersible pumps, \"safe\" levels of shaft voltage, & why not to put one grounding ring at each end of the motor.","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#mainImage","width":300,"height":178,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/#mainImage"},"datePublished":"2021-12-01T13:16:11-05:00","dateModified":"2026-10-22T15:01:00-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/de\/#website","url":"https:\/\/www.est-aegis.com\/de\/","name":"Electro Static Technology","inLanguage":"de-DE","publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A - Part 18","og:description":"Shaft grounding for submersible pumps, &quot;safe&quot; levels of shaft voltage, &amp; why not to put one grounding ring at each end of the motor.","og:url":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg","og:image:width":300,"og:image:height":178,"article:published_time":"2021-12-01T18:16:11+00:00","article:modified_time":"2026-10-22T19:01:00+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A - Part 18","twitter:description":"Shaft grounding for submersible pumps, &quot;safe&quot; levels of shaft voltage, &amp; why not to put one grounding ring at each end of the motor.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg","twitter:label1":"Verfasst von","twitter:data1":"AEGIS","twitter:label2":"Gesch\u00e4tzte Lesedauer","twitter:data2":"3 Minuten"},"aioseo_meta_data":{"post_id":"63","title":"Electrical Bearing Protection Q&A - Part 18","description":"Shaft grounding for submersible pumps, \"safe\" levels of shaft voltage, & why not to put one grounding ring at each end of the motor.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-04 18:52:08","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:45","updated":"2026-11-16 20:16:58","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A \u2013 Part 18\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/de\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A &#8211; Part 18","link":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-18\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/3ph-openwell-submersible-300x178-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/63","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/comments?post=63"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/63\/revisions"}],"predecessor-version":[{"id":10713,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/63\/revisions\/10713"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media\/1035"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media?parent=63"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/categories?post=63"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/tags?post=63"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}