{"id":82,"date":"2020-12-07T16:26:32","date_gmt":"2020-12-07T21:26:32","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=82"},"modified":"2026-10-22T15:01:06","modified_gmt":"2026-10-22T19:01:06","slug":"electrical-bearing-protection-qa-part-7","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A Part 7"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 7 in a series of questions and answers from our Q&amp;A <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">webinars<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><a href=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_20200203_PROMAX724.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"promx_20200203_PROMAX724\" height=\"214\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_20200203_PROMAX724.jpg\" width=\"300\"><\/a>Q1:\u00a0 What&#8217;s the largest motor you can use a shaft grounding ring on?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1:<\/strong>\u00a0 There is no size limit.\u00a0 We routinely make AEGIS<sup>\u00ae<\/sup> rings for turbines over one foot in diameter.\u00a0 The largest ring we&#8217;ve made to date was about 40&#8243;.\u00a0 A lot of these larger rings get used in power generation:\u00a0 wind, water, and other projects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The larger the shaft, the heavier we make the ring.\u00a0 We&#8217;ll upgrade the material to stainless if the application requires a very rigid component.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2:\u00a0 You can have different levels of shaft voltage.\u00a0 Are 15V discharges high enough to cause bearing fluting?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2:<\/strong>\u00a0 Just to be clear:\u00a0 you need an oscilloscope to make these kinds of measurements.\u00a0 That said:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fifteen volts is more than enough charge to damage the bearing when it arcs.\u00a0 We usually see voltage from zero up to 15-20 volts, and occasionally much higher.\u00a0 But the voltage doesn&#8217;t tell you the whole story.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">You also have to consider the discharge frequency, how many times per second you get arcing through the bearing.\u00a0 If you have 15V discharging a few times per second, that&#8217;s bad, but the motor won&#8217;t fail tomorrow.\u00a0 But have you have 15V discharging a few thousand times per second, it&#8217;s going to fail a lot sooner.\u00a0 (You can get an idea of this by setting the trigger level on the scope.\u00a0 If you set it high and the waveform only updates every few seconds, then you&#8217;re not having a lot of discharge at that level.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We like to get the voltage to less than one volt peak.\u00a0 The best way is to measure a baseline, see what it looks like without shaft grounding.\u00a0 Then you use our shaft grounding simulator and test the shaft voltage again to see what it would look like with a grounding ring.\u00a0 Usually, you&#8217;ll go from 15V down to under one volt.\u00a0 As a rule of thumb, anything up to five volts peak is fine.\u00a0 Once you&#8217;re down that low, you can be sure the bearing will last for its usual lifetime.<img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"alignright wp-image-3082\" height=\"209\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/trained-installers-map-300x180-1.png\" width=\"350\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3:\u00a0 What contractor would install a grounding ring, if it&#8217;s not installed by the manufacturer?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3:<\/strong>\u00a0 You should have it done by whomever is going to do the best job.\u00a0 HVAC, electrical, and facilities\/maintenance contractors can do it, and in-house maintenance staff, and so can motor repair contractors.\u00a0 Whoever you have do it, you want to be sure they&#8217;ve got experience.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We have a list of <a href=\"https:\/\/www.est-aegis.com\/where-to-buy\/installers\/\" rel=\"noopener\" target=\"_blank\">trained installers<\/a> on our website.\u00a0 It&#8217;s in a searchable database, so you can find the closest one to you.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4:\u00a0 Can shaft voltage create the white etching effect?\u00a0 This is in a polymer extrusion setup, with motors up to 20 MW.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A4:<\/strong>\u00a0 Yes.\u00a0 High shaft current can basically weld the bearing to the shaft.\u00a0 But there may be other causes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In your case, the first thing to do is take care of the shaft voltage.\u00a0 For a large motor, you want the nondrive end bearing to be insulated.\u00a0 You want a high frequency grounding strap, too.\u00a0 I recommend bonding the strap directly to the grounding ring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With that taken care of, you can start troubleshooting other possible causes.\u00a0 If you think you have a problem with your gearbox, AEGIS rings can also go on gearbox shafts.\u00a0 Typically you don&#8217;t need to shaft ground both the motor and the gearbox, but some of our users have done this when they&#8217;ve had a hard time pinning down the problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In injection molding, everything in the plant has a way of acquiring a nonconductive coating.\u00a0 So we recommend installing the ring inside the motor, to keep it away from the nonconductive goop that deposits on everything.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, &#038; white etching.<\/p>\n","protected":false},"author":7,"featured_media":1282,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-82","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, &amp; white etching.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"de_DE\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A Part 7\" \/>\n\t\t<meta property=\"og:description\" content=\"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, &amp; white etching.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-12-07T21:26:32+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:06+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A Part 7\" \/>\n\t\t<meta name=\"twitter:description\" content=\"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, &amp; white etching.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesedauer\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 Minuten\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A Part 7\",\"headline\":\"Electrical Bearing Protection Q&#038;A Part 7\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/promx_pvw-300x300-1.jpg\",\"width\":300,\"height\":300,\"caption\":\"#image_title\"},\"datePublished\":\"2020-12-07T16:26:32-05:00\",\"dateModified\":\"2026-10-22T15:01:06-04:00\",\"inLanguage\":\"de-DE\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A Part 7\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A Part 7\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/\",\"name\":\"Electrical Bearing Protection Q&A Part 7\",\"description\":\"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, & white etching.\",\"inLanguage\":\"de-DE\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/promx_pvw-300x300-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#mainImage\",\"width\":300,\"height\":300,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/blog\\\/electrical-bearing-protection-qa-part-7\\\/#mainImage\"},\"datePublished\":\"2020-12-07T16:26:32-05:00\",\"dateModified\":\"2026-10-22T15:01:06-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"de-DE\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/de\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A Part 7<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A Part 7","description":"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, & white etching.","canonical_url":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#article","name":"Electrical Bearing Protection Q&A Part 7","headline":"Electrical Bearing Protection Q&#038;A Part 7","author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg","width":300,"height":300,"caption":"#image_title"},"datePublished":"2020-12-07T16:26:32-05:00","dateModified":"2026-10-22T15:01:06-04:00","inLanguage":"de-DE","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/de\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#listItem","name":"Electrical Bearing Protection Q&#038;A Part 7"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A Part 7","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/de\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/de\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/de\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#webpage","url":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/","name":"Electrical Bearing Protection Q&A Part 7","description":"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, & white etching.","inLanguage":"de-DE","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/de\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg","@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#mainImage","width":300,"height":300,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/#mainImage"},"datePublished":"2020-12-07T16:26:32-05:00","dateModified":"2026-10-22T15:01:06-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/de\/#website","url":"https:\/\/www.est-aegis.com\/de\/","name":"Electro Static Technology","inLanguage":"de-DE","publisher":{"@id":"https:\/\/www.est-aegis.com\/de\/#organization"}}]},"og:locale":"de_DE","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A Part 7","og:description":"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, &amp; white etching.","og:url":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg","og:image:width":300,"og:image:height":300,"article:published_time":"2020-12-07T21:26:32+00:00","article:modified_time":"2026-10-22T19:01:06+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A Part 7","twitter:description":"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, &amp; white etching.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg","twitter:label1":"Verfasst von","twitter:data1":"AEGIS","twitter:label2":"Gesch\u00e4tzte Lesedauer","twitter:data2":"3 Minuten"},"aioseo_meta_data":{"post_id":"82","title":"Electrical Bearing Protection Q&A Part 7","description":"In this edition: Potpourri! Maximum shaft sizes, safe shaft voltage levels, which contractors can install AEGIS rings, & white etching.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:26:58","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:49","updated":"2026-11-16 20:18:33","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A Part 7\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/de\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/de\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A Part 7","link":"https:\/\/www.est-aegis.com\/de\/blog\/electrical-bearing-protection-qa-part-7\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/promx_pvw-300x300-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/82","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/comments?post=82"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/82\/revisions"}],"predecessor-version":[{"id":10729,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/posts\/82\/revisions\/10729"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media\/1282"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/media?parent=82"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/categories?post=82"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/de\/wp-json\/wp\/v2\/tags?post=82"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}