{"id":10171,"date":"2021-07-13T10:30:20","date_gmt":"2021-07-13T14:30:20","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=103"},"modified":"2026-10-22T15:01:02","modified_gmt":"2026-10-22T19:01:02","slug":"how-do-vfds-cause-bearing-damage","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/","title":{"rendered":"How Do VFDs Cause Bearing Damage?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"Balanced-Voltage-Condition-630px-300x281\" height=\"281\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg\" width=\"300\">Electric induction motors were designed to be operated on 3-phase sine wave power.\u00a0 This input power is <em>balanced<\/em>, meaning that the three voltage phases cancel each other out (sum to zero).\u00a0 So when phase A is at +460V, phases B &amp; C will be at -230V.\u00a0 (+460V &#8211; 230V &#8211; 230V = 0V.)\u00a0 The <em>common mode voltage<\/em> is the average of the three phases.\u00a0 Since the phases sum to zero, the common mode voltage is also zero when power is properly balanced.\u00a0 When the common mode voltage is zero, the bearings are not usually at risk of electrical bearing damage (except for very large motors, over 500 frame).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But when motors are operated by variable frequency drives (VFDs), the transistors in the drive convert pure sine wave power to a series of positive and negative pulses.\u00a0 Consequently, the input voltage to the motor is never balanced. Instead of each phase voltage being a smooth sine wave, they switch rapidly from positive to zero to negative and back.\u00a0 The phases no longer cancel out, and instead of being zero, the common mode voltage is usually a \u00absquare wave\u00bb or a \u00ab6-step\u00bb voltage waveform.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This nonzero common mode voltage in a motor&#8217;s stator windings causes motor bearings to \u00abcharge up\u00bb like a capacitor.\u00a0 For example, suppose that at one moment, the common mode voltage is positive inside the stator windings.\u00a0 This positive common mode voltage induces a positive voltage on the rotor through capacitive coupling.\u00a0 There is also coupling between the windings and the motor frame.\u00a0 But the frame is grounded, so it remains neutral.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With the rotor now positive and the frame still neutral, there is a voltage difference across the motor&#8217;s bearings between the rotating shaft and motor&#8217;s grounded frame.\u00a0 This voltage across the bearings is usually referred to as <em>shaft voltage<\/em>.\u00a0 The bearings are full of electrically insulating (dielectric) grease, which forms a non-conductive film between the balls and race walls.\u00a0 So electrical current cannot normally flow through the bearings.\u00a0 This is exactly like a capacitor: two conductors separated by a non-conductive dielectric.\u00a0 If you apply a dc voltage to a capacitor, it will \u00abcharge up,\u00bb and store energy, but not let appreciable current flow through&#8230; <strong><em>unless the dielectric breaks down<\/em>.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Every capacitor has a breakdown voltage*; a voltage above which the insulator breaks down and allows a burst of current to flow all at once.\u00a0 This is just like lightning:\u00a0 When the voltage between a cloud and the ground gets big enough, the air &#8211; normally a good insulator &#8211; becomes ionized and suddenly becomes conductive.\u00a0 The result is a rapid discharge: charge flows rapidly through the now-conductive air with the often-destructive release of stored energy.\u00a0 After discharge, the voltage across the capacitor will be zero (or at least much lower).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Now back to the motor:<\/strong>\u00a0 If the shaft voltage builds up high enough, it will discharge by arcing through the bearing:\u00a0 Electrons will leap through the bearing like a miniature lightning bolt, and destructively release the energy that was stored in the bearing&#8217;s capacitance.\u00a0 This arc is called a capacitive discharge current, and the damage it does to bearing surfaces is called EDM (electrical discharge machining).\u00a0 <strong>Capacitive EDM currents can occur in all motors run on VFDs, regardless of their size.<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"Total_Qualitative_Bearing_Currents630px-1\" height=\"292\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Total_Qualitative_Bearing_Currents630px-1.jpg\" width=\"300\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A second form of bearing current produced by VFDs \u2014 high frequency (HF) circulating currents \u2014 results from a high-frequency magnetic flux produced by common mode current (the sum of the currents flowing in each of the three phases).\u00a0 Just like common mode voltage, common mode current is zero when the power to a motor is balanced, but not when the motor is on a drive.\u00a0 HF circulating current is produced by the imbalanced magnetic flux of the common mode current.\u00a0 Circulating current consists of electrons arcing from the shaft through one bearing, running down the frame, and arcing through the other bearing back to the shaft.\u00a0 The frequency range for these currents is in the kHz or MHz.\u00a0 The size of these currents, and the damage they do, depends on motor size.\u00a0 They first become a problem in motors above 100 HP (75 kW).\u00a0 In general, the larger the motor, the greater the damage they cause.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Both capacitive discharge currents and HF circulating currents damage the bearings.\u00a0 Because the bearing lubricant is insulating, these currents can only flow by arcing through the grease.\u00a0 This both degrades the grease and damages the surfaces inside the bearing.\u00a0 This surface damage is directly caused by the electrical arcing through the bearing.\u00a0 Each arc creates a pit, a tiny molten crater where it strikes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"Bearing-Damage-Labeld630px-1\" height=\"282\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Bearing-Damage-Labeld630px-1.jpg\" width=\"225\"><span style=\"letter-spacing: 0.32px; font-size: 19px;\"><\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As the pits accumulate, they lead to visible frosting, and eventually to fluting (washboard-like ridges in the bearing race).\u00a0 As bearings degrade, friction increases, leading to noise, further deterioration of the grease, and the likelihood of total bearing failure and costly unplanned downtime.\u00a0 In fact, this entire process can take place in as little as 3 months!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn how to prevent this electrical bearing damage from VFDs, read the companion article, <a href=\"\/best-practices-bearing-protection?hsLang=en-us\" rel=\"noopener\" target=\"_blank\">Bearing Protection Best Practices<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>*<small>Fo<\/small><small>r a bearing, the exact breakdown voltage w<\/small><small>ill depend on RPM, temperature, loading, state of lubrication, state of wear, and many other variables.\u00a0 In practice, a bearing&#8217;s breakdown voltage is unpredictable, but measured shaft voltages under up to 5V peak (10V peak-peak) are considered safe.\u00a0 Higher shaft voltages are likely to cause discharge.<\/small><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">FAQ<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q1. How can electric motor users determine whether their electric motors are at risk of bearing damage from VFDs?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-weight: bold;\">A1.<\/span> The best way to tell if a motor is at risk of electrical bearing damage is to measure the shaft voltage.\u00a0 You can find details <a href=\"https:\/\/www.est-aegis.com\/bearing-protection\/shaft-voltage-and-bearing-currents\/#how-to-test-for-shaft-voltage\" rel=\"noopener\">here<\/a>, and for more detail, see the <a href=\"https:\/\/www.est-aegis.com\/resources\/handbook\/\" rel=\"noopener\" target=\"_blank\">AEGIS Bearing Protection Handbook<\/a>.\u00a0 There is no hard and fast rule, but if the shaft voltage is above 5V peak, the motor is probably at risk of electrical bearing damage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q2. Are there specific measures or technologies available to mitigate the risk of bearing damage caused by VFDs?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-weight: bold;\">A2.<\/span> Yes, these are detailed in our companion blogpost on Bearing Protection Best Practices, and in our <a href=\"https:\/\/www.est-aegis.com\/resources\/handbook\/\" rel=\"noopener\" target=\"_blank\">Bearing Protection Handbook<\/a>.\u00a0 Briefly, all motors on drives should be equipped with an AEGIS ring, and those over 100hp\/75 kW should have some type of insulation for the bearing at the opposite end from the grounding ring.\u00a0 Proper grounding and bonding practices should be observed in <span style=\"text-decoration: underline;\">all<\/span><span style=\"text-decoration: none;\"> motor installations, with or without a VFD<\/span>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q3. Is there a recommended frequency or schedule for inspecting and maintaining motor bearings to prevent or detect damage early on?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-weight: bold;\">A3. <\/span>There is no hard and fast rule, but motor users should definitely set up a proactive maintenance schedule.\u00a0 <span>The frequency of inspections will vary depending on factors like the criticality of the motors.\u00a0 Typically, motor bearings should be inspected at regular intervals, ranging from monthly to annually, depending on the application and environment.\u00a0 Regular maintenance activities may include visual inspections, vibration analysis, lubrication checks, temperature monitoring, and shaft voltage testing.<\/span><\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.<\/p>\n","protected":false},"author":7,"featured_media":1050,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1065],"tags":[],"class_list":["post-10171","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bearing-damage-basics"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How Do VFDs Cause Bearing Damage?\" \/>\n\t\t<meta property=\"og:description\" content=\"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"281\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-07-13T14:30:20+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:02+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How Do VFDs Cause Bearing Damage?\" \/>\n\t\t<meta name=\"twitter:description\" content=\"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#article\",\"name\":\"How Do VFDs Cause Bearing Damage?\",\"headline\":\"How Do VFDs Cause Bearing Damage?\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Balanced-Voltage-Condition-630px-300x281-1.jpg\",\"width\":300,\"height\":281,\"caption\":\"#image_title\"},\"datePublished\":\"2021-07-13T10:30:20-04:00\",\"dateModified\":\"2026-10-22T15:01:02-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#webpage\"},\"articleSection\":\"Bearing Damage Basics, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"name\":\"Bearing Damage Basics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"position\":2,\"name\":\"Bearing Damage Basics\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/bearing-damage-basics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#listItem\",\"name\":\"How Do VFDs Cause Bearing Damage?\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#listItem\",\"position\":3,\"name\":\"How Do VFDs Cause Bearing Damage?\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"name\":\"Bearing Damage Basics\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/\",\"name\":\"How Do VFDs Cause Bearing Damage?\",\"description\":\"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Balanced-Voltage-Condition-630px-300x281-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#mainImage\",\"width\":300,\"height\":281,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/how-do-vfds-cause-bearing-damage\\\/#mainImage\"},\"datePublished\":\"2021-07-13T10:30:20-04:00\",\"dateModified\":\"2026-10-22T15:01:02-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>How Do VFDs Cause Bearing Damage?<\/title>\n\n","aioseo_head_json":{"title":"How Do VFDs Cause Bearing Damage?","description":"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#article","name":"How Do VFDs Cause Bearing Damage?","headline":"How Do VFDs Cause Bearing Damage?","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg","width":300,"height":281,"caption":"#image_title"},"datePublished":"2021-07-13T10:30:20-04:00","dateModified":"2026-10-22T15:01:02-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#webpage"},"articleSection":"Bearing Damage Basics, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/bearing-damage-basics\/#listItem","name":"Bearing Damage Basics"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/bearing-damage-basics\/#listItem","position":2,"name":"Bearing Damage Basics","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/bearing-damage-basics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#listItem","name":"How Do VFDs Cause Bearing Damage?"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#listItem","position":3,"name":"How Do VFDs Cause Bearing Damage?","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/bearing-damage-basics\/#listItem","name":"Bearing Damage Basics"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/","name":"How Do VFDs Cause Bearing Damage?","description":"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#mainImage","width":300,"height":281,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/#mainImage"},"datePublished":"2021-07-13T10:30:20-04:00","dateModified":"2026-10-22T15:01:02-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"How Do VFDs Cause Bearing Damage?","og:description":"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg","og:image:width":300,"og:image:height":281,"article:published_time":"2021-07-13T14:30:20+00:00","article:modified_time":"2026-10-22T19:01:02+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"How Do VFDs Cause Bearing Damage?","twitter:description":"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"6 minutos"},"aioseo_meta_data":{"post_id":"10171","title":"How Do VFDs Cause Bearing Damage?","description":"How variable frequency drives cause electrical bearing damage, explained as simply but accurately as possible.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-04 18:40:03","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:55","updated":"2026-11-16 21:28:51","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/bearing-damage-basics\/\" title=\"Bearing Damage Basics\">Bearing Damage Basics<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tHow Do VFDs Cause Bearing Damage?\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Bearing Damage Basics","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/bearing-damage-basics\/"},{"label":"How Do VFDs Cause Bearing Damage?","link":"https:\/\/www.est-aegis.com\/es\/blog\/how-do-vfds-cause-bearing-damage\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Balanced-Voltage-Condition-630px-300x281-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/10171","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=10171"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/10171\/revisions"}],"predecessor-version":[{"id":10719,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/10171\/revisions\/10719"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/1050"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=10171"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=10171"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=10171"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}