{"id":109,"date":"2018-02-22T14:27:17","date_gmt":"2018-02-22T19:27:17","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=109"},"modified":"2026-10-22T14:52:17","modified_gmt":"2026-10-22T18:52:17","slug":"http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/","title":{"rendered":"Case Study: Making Motors Last at Time &#038; Life Building in NYC"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Testing VFD driven motors for shaft voltage identifies potential bearing damage risk and avoids down time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Innovative companies like <a href=\"https:\/\/www.akfgroup.com\/services\/\" rel=\"noopener\" target=\"_blank\">AKF Analysis &amp; Testing<\/a> are on the leading edge of technology services to assist building owners in ensuring their mechanical and VFD driven motor systems stay up and running.\u00a0 They deploy highly skilled and experienced vibration analysts and testing specialists from the best in the industry with members from Local 638 and Local 94 and focus on building operations such as chiller plants, air handlers, pumps, and critical system units.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the case study which follows you will see how shaft grounding rings were successfully implemented to improve reliability for a New York City landmark building:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Making Motors Last at Time &amp; Life Building in new York City<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Background on the case study below:<\/strong>\u00a0 <em>In 2007, <strong>Tom O\u2019Connell Jr., a partner in AKFA&amp;T<\/strong>, read about the AEGIS SGR Bearing Protection Ring in a magazine and began the process that could eventually end the bearing damage problem at the Time &amp; Life Building once and for all.\u00a0 He called the ring\u2019s manufacturer, Electro Static Technology, and spoke with Adam Willwerth, the company\u2019s sales and marketing manager.\u00a0 Soon after, the two met face to face, and O\u2019Connell decided to recommend the installation of a single SGR shaft grounding ring on the most problematic of all the HVAC motors at Time &amp; Life.\u00a0 <strong>Ron Perez, the building\u2019s manager of engineering, consented to the experiment,<\/strong> and follow-up testing showed the ring to be so successful at diverting harmful shaft currents that O\u2019Connell decided to make his company a distributor for the ring.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The full case study is available to read or download: <a href=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/TES_TimeLife-Article.pdf\" rel=\"noopener\" target=\"_blank\">Click here to view<\/a>.\u00a0 We have also re-published it in this blog.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Making HVAC fan motors last was the goal for tenants of the Time &amp; Life Building, in New York\u2019s Rockefeller Center: Shaft grounding rings were installed to prevent an on-going bearing failure problem with remarkable success.\u00a0 Installed in 2008, these motors are still running today!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"Time and Life Building\" class=\"aligncenter wp-image-1024 size-full\" height=\"224\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg\" width=\"430\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Time and Life Building, New York City<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A preventive maintenance plan that reduces the total life-cycle cost of operations in a prominent building at the heart of New York City serves as a good example of how the push for greater reliability and up-time in building management has led to finding a solution to a chronic, widespread problem with HVAC motors \u2013 electrical bearing damage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The problem is all too common in AC motors controlled by variable frequency drives (VFDs), which are also known as inverters, adjustable speed drives, etc. These drives are widely used because they can save energy, especially in applications with varying loads. Because many centrifugal fans and pumps run continuously, their motors will use less power if the input is modulated by VFDs.\u00a0 For example, a 20% reduction in fan speed can reduce energy consumption by nearly 50%. With rising energy costs, the use of throttling mechanisms to restrict the work of a motor running at full speed would be wasteful.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, efficiency alone is not enough if equipment keeps breaking down. That is what was happening at the 48-story Time &amp; Life Building, one of 19 buildings in the Manhattan business and entertainment complex built and partially owned by the Rockefeller Group and known as Rockefeller Center.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">More than 100 VFDs control the speeds of the 240 motors that run the building\u2019s HVAC fans and pumps. Unfortunately, a large portion of the savings from these systems has been wiped out by maintenance costs because, in addition to their intended function, VFDs induce powerful, unwanted currents which cause electrical bearing discharges and, ultimately, premature motor failure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">SHAFT GROUNDING<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Proper tuning of a drive\u2019s frequency output range and proper grounding of a VFD-controlled motor\u2019s frame are paramount. Only recently has it become clear that without an effective shaft-grounding device as well, stray currents can wreak havoc with bearings, causing premature motor failure. Ironically, some products designed to protect bearings, such as conventional<br>metal grounding brushes, require extensive maintenance themselves. Others, such as insulation, can shift damage to connected equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"AEGIS shaft grounding diagram\" class=\"size-full wp-image-181 alignright\" height=\"247\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lunch-and-learn-2.jpg\" width=\"320\">One of the newest and most promising bearing-damage mitigation devices uses patented shaft grounding ring technology to safely bleed off these damaging currents to ground.\u00a0 Engineered with special conductive microfibers, the AEGIS shaft grounding ring safely discharges VFD-induced shaft voltages by providing a very low impedance path from shaft to frame, bypassing the motor\u2019s bearings entirely.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For more than 20 years, since the installation of the first modern VFDs, the Time &amp; Life Building\u2019s maintenance department has dealt with chronic motor and bearing failure. At times, the bearing damage had advanced to the noisy stage, at which an unpleasant, high-pitched sound was transmitted through duct-work. Thanks to the efforts of AKF Analysis &amp; Testing, an engineering firm hired by the Rockefeller Group Development Corp. to periodically test and tune (with harmonic filters) the building\u2019s VFDs, the rate of motor\/bearing replacements has dropped from 90 to 20 per year, but in today\u2019s economy that is still too costly. Other attempts to mitigate the problem, including the installation of ceramic bearings on some motors, have produced mixed results, usually proving too costly for the meager improvements gained.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">THE SOLUTION AT LAST<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Late in 2007 AKF Analysis and Testing read about the AEGIS shaft grounding ring and began the process that could eventually end the bearing damage problem at the Time &amp; Life Building once and for all.\u00a0\u00a0 AKF A&amp;T decided to recommend the installation of a single shaft grounding ring on the most problematic of all the HVAC motors at Time &amp; Life.\u00a0 Ron Perez, the building\u2019s manager of engineering, consented to the experiment, and follow-up testing showed the ring to be so successful at diverting harmful shaft currents that O\u2019Connell decided to make his company a distributor for the ring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"fan motor\" class=\"aligncenter wp-image-1020 size-medium\" height=\"261\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Time-and-Life-AGIS-installation-300x261-1.jpg\" width=\"300\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fan motor in the Time &amp; Life Building with AEGIS Ring installed by AKF Analysis and Testing<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It was an unprecedented move.\u00a0 AKF A&amp;T specializes in vibration monitoring and analysis, acceptance testing, critical speed testing, and motor current waveform analysis for preventive maintenance and energy management on behalf of government agencies and businesses in a multitude of East Coast buildings, including hotels, hospitals, laboratories, and office buildings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Never before had the company endorsed a particular product.\u00a0 The whole phenomenon of electrical bearing damage is so misunderstood that some maintenance managers have lost their jobs over it because replacing a fan motor is a big expense.\u00a0\u00a0 In an office tower, a motor can be running critical equipment<br>that supplies air to 30 floors where the tenants are paying as much as $110 a square foot.\u00a0 They have the right to expect the temperature and quality of their air to remain constant.\u00a0 AKF A&amp;T was so convinced of the ring\u2019s effectiveness that they recommended it be eventually installed on all HVAC motors in the Time &amp; Life Building and in other buildings for which they have contracts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because AKF Analysis and Testing usually visit a client\u2019s building three or four times a year to run diagnostic tests on the HVAC equipment and tune the VFDs, they have seen the progression of motor bearing damage.\u00a0 Now, the typical procedure is to recommend installation of an AEGIS shaft grounding ring whenever a replacement motor is installed or a motor\u2019s bearings are replaced to ensure that harmful bearing currents have been eliminated and the VFD is running at its optimal performance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">THE EXPERIMENT<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"shaft voltage readings\" class=\"aligncenter wp-image-1021 size-medium\" height=\"300\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Before-and-After-Voltage-228x300-1.png\" width=\"228\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Shaft Voltage readings before and after one year<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">On February 6, 2008, before the ring was installed on the problematic motor, AKF A&amp;T used a shaft voltage probe and an oscilloscope to measure the discharges from the motor&#8217;s shaft at 59.2V (peak-to peak) and 37.2V (peak-to-peak), at two different oscilloscope settings (10\u03bcsec\/ div and 2\u03bcsec\/div, respectively), for an average of 48.2V (peak-to-peak). The oscilloscope screen showed rapid dv\/dt voltage collapse at the trailing edge of the waveform \u2013 typical of the electrical discharges that damage bearings. On February 20, 2008, two weeks after the ring was installed, AKFA&amp;T took a ground-reference reading, for baseline comparison, of 9.21V (peak to-peak) with the oscilloscope set at 40ns\/div. Minutes later, AKF A&amp;T took two more shaft-current readings at the same setting: 8.86V (peak-to-peak) and 11.2V (peak-to-peak).\u00a0 A little more than a year later, on March 9, 2009, the motor was checked again by AKFA&amp;T technicians. This time the shaft voltage was even lower: 4.8V (peak-to-peak).\u00a0 The readings may speak for themselves and the Building engineering manager Perez agrees the ring \u201cseems to have resolved the issue.\u201d Based on the positive results, he has installed AEGIS shaft grounding rings on additional fan motors in the Time &amp; Life Building.<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Case Study: Making Motors Last at Time &#038; Life Building in NYC<\/p>\n","protected":false},"author":7,"featured_media":9612,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1068],"tags":[],"class_list":["post-109","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-case-studies"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Case Study: Making Motors Last at Time &amp; Life Building in NYC\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Case Study: Making Motors Last at Time &amp; Life Building in NYC\" \/>\n\t\t<meta property=\"og:description\" content=\"Case Study: Making Motors Last at Time &amp; Life Building in NYC\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"430\" \/>\n\t\t<meta property=\"og:image:height\" content=\"224\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2018-02-22T19:27:17+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T18:52:17+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Case Study: Making Motors Last at Time &amp; Life Building in NYC\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Case Study: Making Motors Last at Time &amp; Life Building in NYC\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"7 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#article\",\"name\":\"Case Study: Making Motors Last at Time & Life Building in NYC\",\"headline\":\"Case Study: Making Motors Last at Time &#038; Life Building in NYC\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/testing-timelife-1-e1519326186749.jpg\",\"width\":430,\"height\":224,\"caption\":\"#image_title\"},\"datePublished\":\"2018-02-22T14:27:17-05:00\",\"dateModified\":\"2026-10-22T14:52:17-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#webpage\"},\"articleSection\":\"Case Studies, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/case-studies\\\/#listItem\",\"name\":\"Case Studies\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/case-studies\\\/#listItem\",\"position\":2,\"name\":\"Case Studies\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/case-studies\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#listItem\",\"name\":\"Case Study: Making Motors Last at Time &#038; Life Building in NYC\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#listItem\",\"position\":3,\"name\":\"Case Study: Making Motors Last at Time &#038; Life Building in NYC\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/case-studies\\\/#listItem\",\"name\":\"Case Studies\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/\",\"name\":\"Case Study: Making Motors Last at Time & Life Building in NYC\",\"description\":\"Case Study: Making Motors Last at Time & Life Building in NYC\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/testing-timelife-1-e1519326186749.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#mainImage\",\"width\":430,\"height\":224,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\\\/#mainImage\"},\"datePublished\":\"2018-02-22T14:27:17-05:00\",\"dateModified\":\"2026-10-22T14:52:17-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Case Study: Making Motors Last at Time &amp; Life Building in NYC<\/title>\n\n","aioseo_head_json":{"title":"Case Study: Making Motors Last at Time & Life Building in NYC","description":"Case Study: Making Motors Last at Time & Life Building in NYC","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#article","name":"Case Study: Making Motors Last at Time & Life Building in NYC","headline":"Case Study: Making Motors Last at Time &#038; Life Building in NYC","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg","width":430,"height":224,"caption":"#image_title"},"datePublished":"2018-02-22T14:27:17-05:00","dateModified":"2026-10-22T14:52:17-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#webpage"},"articleSection":"Case Studies, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/case-studies\/#listItem","name":"Case Studies"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/case-studies\/#listItem","position":2,"name":"Case Studies","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/case-studies\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#listItem","name":"Case Study: Making Motors Last at Time &#038; Life Building in NYC"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#listItem","position":3,"name":"Case Study: Making Motors Last at Time &#038; Life Building in NYC","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/case-studies\/#listItem","name":"Case Studies"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/","name":"Case Study: Making Motors Last at Time & Life Building in NYC","description":"Case Study: Making Motors Last at Time & Life Building in NYC","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#mainImage","width":430,"height":224,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/#mainImage"},"datePublished":"2018-02-22T14:27:17-05:00","dateModified":"2026-10-22T14:52:17-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Case Study: Making Motors Last at Time &amp; Life Building in NYC","og:description":"Case Study: Making Motors Last at Time &amp; Life Building in NYC","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg","og:image:width":430,"og:image:height":224,"article:published_time":"2018-02-22T19:27:17+00:00","article:modified_time":"2026-10-22T18:52:17+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Case Study: Making Motors Last at Time &amp; Life Building in NYC","twitter:description":"Case Study: Making Motors Last at Time &amp; Life Building in NYC","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"7 minutos"},"aioseo_meta_data":{"post_id":"109","title":"Case Study: Making Motors Last at Time & Life Building in NYC","description":"Case Study: Making Motors Last at Time & Life Building in NYC","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:38:17","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:56","updated":"2026-11-16 20:21:44","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/case-studies\/\" title=\"Case Studies\">Case Studies<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tCase Study: Making Motors Last at Time &amp; Life Building in NYC\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Case Studies","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/case-studies\/"},{"label":"Case Study: Making Motors Last at Time &#038; Life Building in NYC","link":"https:\/\/www.est-aegis.com\/es\/blog\/http-akfgroup-com-resources-pdfs-articles-10_03time_life-pdf\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/testing-timelife-1-e1519326186749.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=109"}],"version-history":[{"count":2,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/109\/revisions"}],"predecessor-version":[{"id":10603,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/109\/revisions\/10603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/9612"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}