{"id":11,"date":"2023-05-10T09:00:00","date_gmt":"2023-05-10T13:00:00","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=11"},"modified":"2026-10-22T15:00:50","modified_gmt":"2026-10-22T19:00:50","slug":"aegis-in-wind-turbine-generators","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/","title":{"rendered":"AEGIS Shaft Grounding in Wind Turbine Generators"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Along with solar power, wind power is the fastest-growing <a href=\"https:\/\/www.est-aegis.com\/applications\/power-generation-renewable-energy\/\" rel=\"noopener\">renewable energy source<\/a>.\u00a0 Wind turbine generators work by capturing energy from the wind and using it to spin the generator shaft, producing electric power.\u00a0 These generators use a gearbox and an inverter drive (a.k.a. VFD) to match the power output&#8217;s frequency to grid power&#8217;s 50 or 60 Hz.\u00a0 Most also use inverters to excite the generator, while others use permanent magnets.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">VFDs, Stray Voltage, and the Generator Shaft<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">But VFDs also create voltage on the generator shaft. This voltage will discharge to ground by any available low-resistance path. Unfortunately, these paths usually lead through the generator or gearbox bearings. Discharge through these moving parts causes cumulative electrical discharge machining damage. In bearings, the damage is called fluting; in gearboxes, it&#8217;s called tiger-striping. Whatever you call it, electrical damage causes generator failure. And failure means expensive repairs and downtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"fluting1\" height=\"214\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting1.jpg\" width=\"300\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Wind Generator Electrical Bearing Damage<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Most generators have hybrid or insulated bearings that resist electrical damage from discharge and circulating currents. But coupled equipment, like gearboxes and tachometers, is left vulnerable. So wind generators also include rotor grounding to reduce the risk to this equipment. Inverter-excited generators use a carbon shaft grounding brush, and permanent magnet designs use rollers on the brake disk. Both methods provide a low-resistance path to low-frequency and DC current. So this otherwise destructive current goes harmlessly through the brush or roller.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But shaft voltage contains high and low frequencies, and brushes and rollers have high impedance (resistance) to high-frequency electricity. So even with a brush or roller, the system is still at risk of electrical damage. Wind turbine generators also need a form of shaft grounding with low impedance at high frequencies.\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Does a Wind Turbine Need Shaft Grounding?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"PRO_UnivBrac-and-Solid_silo\" height=\"300\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/PRO_UnivBrac-and-Solid_silo-1.png\" width=\"300\">The short answer is yes, and AEGIS<sup>\u00ae<\/sup> Shaft Grounding Rings are part of the solution. AEGIS PRO Series Rings surround the shaft with hundreds of thousands of conductive microfibers.\u00a0 These fibers have a high surface area, which gives them low impedance to high-frequency current.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With hybrid bearings to block circulating currents, a roller or carbon brush to carry dc and low-frequency current, and an AEGIS Ring for high frequencies, the system is fully protected against electrical bearing damage.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">In the Field: Testing for a Wind Generator Manufacturer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Jens Leipner, the AEGIS Sales Manager for Northern Europe, recently went up-tower to do testing for a wind generator manufacturer.\u00a0 The test site was a 455-foot tall turbine (140m) turbine with 440-foot blades. The generator itself was a permanent magnet\/VFD model. It had rollers on the brake disk for low-frequency grounding and a \u00abviolin string\u00bb shaft grounding device for high frequencies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"jens-20191105-WA0002\" height=\"533\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/jens-20191105-WA0002.jpg\" width=\"300\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With no shaft grounding, the shaft voltage was 20 volts peak to peak.\u00a0 With the shaft grounding string, the voltage was brought down to a little over four volts.\u00a0 This is a safe level, but the grounding string showed severe wear.\u00a0 Because these devices are pressed, under tension, against a spinning shaft, they can quickly wear through.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When AEGIS PRO Ring segments were installed, the shaft voltage was decreased to safe levels of less than a volt.\u00a0 Further, the AEGIS Ring&#8217;s fibers are not under tension; they only press lightly against the shaft.\u00a0 This makes them much longer-lived than grounding strings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With long lifetimes and low impedance at high frequencies, AEGIS grounding rings are wind turbine generators&#8217; most effective grounding systems for high-frequency shaft voltage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We can visit your site and give an in-person training with an emphasis on your specific focus.\u00a0 We also offer monthly live training webinars.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Wind turbine generators are prone to electrical bearing damage, premature bearing failure, &#038; unplanned downtime- if they&#8217;re not protected with AEGIS Rings.<\/p>\n","protected":false},"author":7,"featured_media":1214,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1064],"tags":[],"class_list":["post-11","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications-and-industries"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, &amp; unplanned downtime- if they&#039;re not protected with AEGIS Rings.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Shaft Grounding Improves Wind Turbine Generator Reliability\" \/>\n\t\t<meta property=\"og:description\" content=\"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, &amp; unplanned downtime- if they&#039;re not protected with AEGIS Rings.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"160\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-05-10T13:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:00:50+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Shaft Grounding Improves Wind Turbine Generator Reliability\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, &amp; unplanned downtime- if they&#039;re not protected with AEGIS Rings.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#article\",\"name\":\"Shaft Grounding Improves Wind Turbine Generator Reliability\",\"headline\":\"AEGIS Shaft Grounding in Wind Turbine Generators\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/fluting-598-300x160-1.gif\",\"width\":300,\"height\":160,\"caption\":\"#image_title\"},\"datePublished\":\"2023-05-10T09:00:00-04:00\",\"dateModified\":\"2026-10-22T15:00:50-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#webpage\"},\"articleSection\":\"Applications &amp; Industries, Opcional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"position\":2,\"name\":\"Applications &amp; Industries\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/applications-and-industries\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#listItem\",\"name\":\"AEGIS Shaft Grounding in Wind Turbine Generators\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#listItem\",\"position\":3,\"name\":\"AEGIS Shaft Grounding in Wind Turbine Generators\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/\",\"name\":\"Shaft Grounding Improves Wind Turbine Generator Reliability\",\"description\":\"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, & unplanned downtime- if they're not protected with AEGIS Rings.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/fluting-598-300x160-1.gif\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#mainImage\",\"width\":300,\"height\":160,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/aegis-in-wind-turbine-generators\\\/#mainImage\"},\"datePublished\":\"2023-05-10T09:00:00-04:00\",\"dateModified\":\"2026-10-22T15:00:50-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Shaft Grounding Improves Wind Turbine Generator Reliability<\/title>\n\n","aioseo_head_json":{"title":"Shaft Grounding Improves Wind Turbine Generator Reliability","description":"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, & unplanned downtime- if they're not protected with AEGIS Rings.","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#article","name":"Shaft Grounding Improves Wind Turbine Generator Reliability","headline":"AEGIS Shaft Grounding in Wind Turbine Generators","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif","width":300,"height":160,"caption":"#image_title"},"datePublished":"2023-05-10T09:00:00-04:00","dateModified":"2026-10-22T15:00:50-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#webpage"},"articleSection":"Applications &amp; Industries, Opcional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/applications-and-industries\/#listItem","position":2,"name":"Applications &amp; Industries","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/applications-and-industries\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#listItem","name":"AEGIS Shaft Grounding in Wind Turbine Generators"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#listItem","position":3,"name":"AEGIS Shaft Grounding in Wind Turbine Generators","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/","name":"Shaft Grounding Improves Wind Turbine Generator Reliability","description":"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, & unplanned downtime- if they're not protected with AEGIS Rings.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif","@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#mainImage","width":300,"height":160,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/#mainImage"},"datePublished":"2023-05-10T09:00:00-04:00","dateModified":"2026-10-22T15:00:50-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Shaft Grounding Improves Wind Turbine Generator Reliability","og:description":"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, &amp; unplanned downtime- if they're not protected with AEGIS Rings.","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif","og:image:width":300,"og:image:height":160,"article:published_time":"2023-05-10T13:00:00+00:00","article:modified_time":"2026-10-22T19:00:50+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Shaft Grounding Improves Wind Turbine Generator Reliability","twitter:description":"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, &amp; unplanned downtime- if they're not protected with AEGIS Rings.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"3 minutos"},"aioseo_meta_data":{"post_id":"11","title":"Shaft Grounding Improves Wind Turbine Generator Reliability","description":"Wind turbine generators are prone to electrical bearing damage, premature bearing failure, & unplanned downtime- if they're not protected with AEGIS Rings.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:39:48","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:31","updated":"2026-11-16 20:10:36","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/applications-and-industries\/\" title=\"Applications &amp; Industries\">Applications &amp; Industries<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tAEGIS Shaft Grounding in Wind Turbine Generators\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Applications &amp; Industries","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/applications-and-industries\/"},{"label":"AEGIS Shaft Grounding in Wind Turbine Generators","link":"https:\/\/www.est-aegis.com\/es\/blog\/aegis-in-wind-turbine-generators\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/fluting-598-300x160-1.gif","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/11","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=11"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/11\/revisions"}],"predecessor-version":[{"id":10681,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/11\/revisions\/10681"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/1214"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=11"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=11"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=11"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}