{"id":114,"date":"2022-04-11T11:49:00","date_gmt":"2022-04-11T15:49:00","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=114"},"modified":"2026-10-22T15:00:57","modified_gmt":"2026-10-22T19:00:57","slug":"inductive-absorbers-cannot-substitute-for-shaft-grounding","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/","title":{"rendered":"Inductive Absorbers Cannot Substitute for Shaft Grounding"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">We got an email recently from an engineering consultant.\u00a0 He had recently specified a project calling for AEGIS Shaft Grounding Rings for motors controlled by variable frequency drives.\u00a0 Then a contractor put in a bid including, not shaft grounding, but common mode chokes or inductive absorbers.\u00a0 He said that they do the same thing as shaft grounding.\u00a0 Well, the engineer wanted to know, is that true?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img decoding=\"async\" class=\"alignright\" alt=\"CMV+CMI-no-choke-disp240x300\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png\" width=\"350\"><span style=\"font-weight: normal;\">They do not.\u00a0 To see why, let&#8217;s have a look at what drives&#8217; output looks like, and then talk about what each of these devices does.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span style=\"font-weight: bold;\">What is Common Mode Voltage?<\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">VFDs put out pulses of voltage in each of the three phases. The average of the three phase voltages is called <em>common mode voltage<\/em> (top graph, blue), and it is never zero.\u00a0 The average of the phase currents, the <em>common mode current<\/em> (bottom graph), is near zero most of the time, but it jumps every time the common-mode voltage changes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Difference Between Common Mode Voltage and Shaft Voltage<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">When the common mode voltage reaches the motor,\u00a0it couples to the rotor by capacitance.\u00a0 This creates a so-called <em>shaft voltage<\/em> (top, orange).\u00a0 This part is important:\u00a0 <em>The higher the common mode voltage, the higher the shaft voltage produced<\/em>.\u00a0 When the shaft voltage gets too high, it will discharge by arcing through the bearings.\u00a0 This is shown around time = 18 on the graph: the shaft voltage drops suddenly, the smoking gun of an arc.\u00a0 The same thing happens around time = 115, but starting from negative shaft voltage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This arcing causes electrical bearing damage, and it is a problem in <em>all<\/em> motors on drives.\u00a0 AEGIS rings prevent this damage by bleeding off shaft voltage before it gets high enough to discharge through the bearings.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-with-choke-disp240x300.png\" alt=\"CMV+CMI-with-choke-disp240x300\" style=\"width:350px\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">How Do Inductive Absorbers Work?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Inductive absorbers work totally differently.\u00a0 They decrease the peak common mode currrent, as shown in the second set of graphs.\u00a0 They also decrease the slope of the common mode voltage, i.e., how fast it changes.\u00a0 (Jargon alert: they decrease dv\/dt.)\u00a0 But inductors do <span style=\"text-decoration: underline;\">not<\/span> change the maximum size\/height of the common mode voltage, so they will not prevent shaft voltage buildup and discharge.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Types of Electrical Bearing Damage<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In fairness, inductive cores do have their uses.\u00a0 In addition to shaft voltage discharge, there are two other types of electrical bearing damage:\u00a0 High-frequency circulating current in large motors, over 100 HP\/75 kW, and rotor ground current in poorly grounded motors.\u00a0 Inductive absorbers decrease both of those bearing currents, and they also reduce stray\/noise current from the drive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But they do not affect shaft voltage buildup and discharge, and so cannot replace <a href=\"https:\/\/www.est-aegis.com\/products\/\" rel=\"noopener\" target=\"_blank\">AEGIS Shaft Grounding Rings<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They&#8217;re NOT interchangeable.<\/p>\n","protected":false},"author":7,"featured_media":8562,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1067],"tags":[],"class_list":["post-114","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-and-selection"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They&#039;re NOT interchangeable.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Can Inductive Absorbers Substitute for Shaft Grounding?\" \/>\n\t\t<meta property=\"og:description\" content=\"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They&#039;re NOT interchangeable.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1654\" \/>\n\t\t<meta property=\"og:image:height\" content=\"2065\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2022-04-11T15:49:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:00:57+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Can Inductive Absorbers Substitute for Shaft Grounding?\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They&#039;re NOT interchangeable.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#article\",\"name\":\"Can Inductive Absorbers Substitute for Shaft Grounding?\",\"headline\":\"Inductive Absorbers Cannot Substitute for Shaft Grounding\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/CMVCMI-no-choke-disp240x300.png\",\"width\":1654,\"height\":2065,\"caption\":\"#image_title\"},\"datePublished\":\"2022-04-11T11:49:00-04:00\",\"dateModified\":\"2026-10-22T15:00:57-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#webpage\"},\"articleSection\":\"Product &amp; Selection, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/product-and-selection\\\/#listItem\",\"name\":\"Product &amp; Selection\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/product-and-selection\\\/#listItem\",\"position\":2,\"name\":\"Product &amp; Selection\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/product-and-selection\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#listItem\",\"name\":\"Inductive Absorbers Cannot Substitute for Shaft Grounding\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#listItem\",\"position\":3,\"name\":\"Inductive Absorbers Cannot Substitute for Shaft Grounding\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/product-and-selection\\\/#listItem\",\"name\":\"Product &amp; Selection\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/\",\"name\":\"Can Inductive Absorbers Substitute for Shaft Grounding?\",\"description\":\"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They're NOT interchangeable.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/CMVCMI-no-choke-disp240x300.png\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#mainImage\",\"width\":1654,\"height\":2065,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/inductive-absorbers-cannot-substitute-for-shaft-grounding\\\/#mainImage\"},\"datePublished\":\"2022-04-11T11:49:00-04:00\",\"dateModified\":\"2026-10-22T15:00:57-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Can Inductive Absorbers Substitute for Shaft Grounding?<\/title>\n\n","aioseo_head_json":{"title":"Can Inductive Absorbers Substitute for Shaft Grounding?","description":"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They're NOT interchangeable.","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#article","name":"Can Inductive Absorbers Substitute for Shaft Grounding?","headline":"Inductive Absorbers Cannot Substitute for Shaft Grounding","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png","width":1654,"height":2065,"caption":"#image_title"},"datePublished":"2022-04-11T11:49:00-04:00","dateModified":"2026-10-22T15:00:57-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#webpage"},"articleSection":"Product &amp; Selection, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/product-and-selection\/#listItem","name":"Product &amp; Selection"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/product-and-selection\/#listItem","position":2,"name":"Product &amp; Selection","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/product-and-selection\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#listItem","name":"Inductive Absorbers Cannot Substitute for Shaft Grounding"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#listItem","position":3,"name":"Inductive Absorbers Cannot Substitute for Shaft Grounding","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/product-and-selection\/#listItem","name":"Product &amp; Selection"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/","name":"Can Inductive Absorbers Substitute for Shaft Grounding?","description":"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They're NOT interchangeable.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png","@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#mainImage","width":1654,"height":2065,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/#mainImage"},"datePublished":"2022-04-11T11:49:00-04:00","dateModified":"2026-10-22T15:00:57-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Can Inductive Absorbers Substitute for Shaft Grounding?","og:description":"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They're NOT interchangeable.","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png","og:image:width":1654,"og:image:height":2065,"article:published_time":"2022-04-11T15:49:00+00:00","article:modified_time":"2026-10-22T19:00:57+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Can Inductive Absorbers Substitute for Shaft Grounding?","twitter:description":"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They're NOT interchangeable.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"3 minutos"},"aioseo_meta_data":{"post_id":"114","title":"Can Inductive Absorbers Substitute for Shaft Grounding?","description":"Shaft grounding and common mode chokes both protect motor bearings, but they work in very different ways. They're NOT interchangeable.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:41:23","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:57","updated":"2026-11-16 20:23:19","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/product-and-selection\/\" title=\"Product &amp; Selection\">Product &amp; Selection<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tInductive Absorbers Cannot Substitute for Shaft Grounding\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Product &amp; Selection","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/product-and-selection\/"},{"label":"Inductive Absorbers Cannot Substitute for Shaft Grounding","link":"https:\/\/www.est-aegis.com\/es\/blog\/inductive-absorbers-cannot-substitute-for-shaft-grounding\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CMVCMI-no-choke-disp240x300.png","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/114","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=114"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/114\/revisions"}],"predecessor-version":[{"id":10704,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/114\/revisions\/10704"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/8562"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=114"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=114"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=114"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}