{"id":59,"date":"2021-08-03T10:28:14","date_gmt":"2021-08-03T14:28:14","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=59"},"modified":"2026-10-22T15:01:01","modified_gmt":"2026-10-22T19:01:01","slug":"electrical-bearing-protection-qa-part-14","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A Part 14"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 14 in a series of questions and answers from our Q&amp;A <strong><a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">webinars<\/a><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1: Does the discharge current oscillate polarity?\u00a0 I often see shaft voltage plots with what looks like positive and negative discharge spikes.<img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"pos-neg\" height=\"237\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg.jpg\" width=\"300\"><br><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1:<\/strong> Short answer:\u00a0 yes.\u00a0 We focus on the \u00abpositive\u00bb discharges (center in the figure) because it&#8217;s intuitive to think of something unstable \u00abbuilding up\u00bb and then crashing back to the ground.\u00a0 In fact the motor shaft and rotor can be positive <span style=\"text-decoration: underline;\">or<\/span> negatively charged relative to the frame.\u00a0 Regardless of the shaft voltage polarity, damage will be done if it arcs through the bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2.\u00a0 Is the grounding ring appropriate for a dusty environment like a mine, or could accumulated dust interfere with its function?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2:<\/strong> AEGIS<sup>\u00ae<\/sup> rings have been used inside plenty of mines and paper mills.\u00a0 These are some of the dustiest, dirtiest environments on earth.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The rings are resilient against moderate amounts of dust.\u00a0 Their fibers tend to sweep the motor shaft clean.\u00a0 In dirtier environments, you can also slip an O ring up the shaft, or use a slinger or other protective cover.\u00a0 If that&#8217;s not enough, the AEGIS ring can always be installed inside the motor, either by the manufacturer or by a motor repair contractor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3.\u00a0 What are the pros and cons of AEGIS rings compared with inductive absorbers?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3: <\/strong>We answered a related question in our last Q&amp;A about inductive filters inside of drives.\u00a0 In brief, AEGIS rings and inductive absorbers do different things, and protect against different things.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There are three ways VFDs can damage motor bearings:\u00a0 #1, shaft voltage discharge current, #2 high-frequency circulating current, and #3 rotor ground current.\u00a0 Shaft voltage discharge is a problem in all motors on drives.\u00a0 It is caused by the common mode voltage of the drive&#8217;s output.\u00a0 Circulating currents are only a problem in larger motors, over 100 hp (75 kW), and rotor ground current is a problem when the motor is not well-grounded.\u00a0 These two are caused by common mode <span style=\"text-decoration: underline;\">current<\/span> in the drive&#8217;s ouptut.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS rings primarily protect against shaft voltage discharge, #1.\u00a0 Inductive cores protect against #2 and #3.\u00a0 These chokes reduce peak common mode current, but they barely affect common mode voltage.\u00a0 But the common mode <span style=\"text-decoration: underline;\">voltage<\/span> is what produces the shaft voltage.\u00a0 So while inductive absorbers reduce bearing currents #2 and #3, they do not do not protect against #1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is clear in the shaft voltage readings below.\u00a0 On the left is a motor without an inductive absorber.\u00a0 The shaft voltage (yellow) builds up and then collapses.\u00a0 That collapse means an arc through the bearing.\u00a0 On the right is a motor with an inductive absorber.\u00a0 The shaft voltage builds up and again, discharges by arcing through the bearing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CB-current-voltage-not-a-jot-1.jpg\"><img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"aligncenter wp-image-3377\" height=\"294\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/CB-current-voltage-not-a-jot-300x147-1.jpg\" width=\"600\"><\/a> Shaft voltage without (left) and with (right) an inductive filter. Shaft voltage builds up and arcs through the bearing either way.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Common mode chokes or inductive absorbers cannot protect against shaft voltage discharge current.\u00a0 If you use chokes, you need a second type of protection against bearing current #1.\u00a0 There are many options, but an AEGIS Shaft Grounding Ring is usually the most practical.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>In this installment of AEGIS Q&#038;A, we talk about shaft voltage polarity, dusty environments, &#038; inductive cores.<\/p>\n","protected":false},"author":7,"featured_media":1277,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-59","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"In this installment of AEGIS Q&amp;A, we talk about shaft voltage polarity, dusty environments, &amp; inductive cores.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A Part 14\" \/>\n\t\t<meta property=\"og:description\" content=\"In this installment of AEGIS Q&amp;A, we talk about shaft voltage polarity, dusty environments, &amp; inductive cores.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"237\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-08-03T14:28:14+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:01+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A Part 14\" \/>\n\t\t<meta name=\"twitter:description\" content=\"In this installment of AEGIS Q&amp;A, we talk about shaft voltage polarity, dusty environments, &amp; inductive cores.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A Part 14\",\"headline\":\"Electrical Bearing Protection Q&#038;A Part 14\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/pos-neg-300x237-1.jpg\",\"width\":300,\"height\":237,\"caption\":\"#image_title\"},\"datePublished\":\"2021-08-03T10:28:14-04:00\",\"dateModified\":\"2026-10-22T15:01:01-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A Part 14\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A Part 14\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/\",\"name\":\"Electrical Bearing Protection Q&A Part 14\",\"description\":\"In this installment of AEGIS Q&A, we talk about shaft voltage polarity, dusty environments, & inductive cores.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/pos-neg-300x237-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#mainImage\",\"width\":300,\"height\":237,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-14\\\/#mainImage\"},\"datePublished\":\"2021-08-03T10:28:14-04:00\",\"dateModified\":\"2026-10-22T15:01:01-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A Part 14<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A Part 14","description":"In this installment of AEGIS Q&A, we talk about shaft voltage polarity, dusty environments, & inductive cores.","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#article","name":"Electrical Bearing Protection Q&A Part 14","headline":"Electrical Bearing Protection Q&#038;A Part 14","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg","width":300,"height":237,"caption":"#image_title"},"datePublished":"2021-08-03T10:28:14-04:00","dateModified":"2026-10-22T15:01:01-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#listItem","name":"Electrical Bearing Protection Q&#038;A Part 14"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A Part 14","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/","name":"Electrical Bearing Protection Q&A Part 14","description":"In this installment of AEGIS Q&A, we talk about shaft voltage polarity, dusty environments, & inductive cores.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#mainImage","width":300,"height":237,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/#mainImage"},"datePublished":"2021-08-03T10:28:14-04:00","dateModified":"2026-10-22T15:01:01-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A Part 14","og:description":"In this installment of AEGIS Q&amp;A, we talk about shaft voltage polarity, dusty environments, &amp; inductive cores.","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg","og:image:width":300,"og:image:height":237,"article:published_time":"2021-08-03T14:28:14+00:00","article:modified_time":"2026-10-22T19:01:01+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A Part 14","twitter:description":"In this installment of AEGIS Q&amp;A, we talk about shaft voltage polarity, dusty environments, &amp; inductive cores.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"3 minutos"},"aioseo_meta_data":{"post_id":"59","title":"Electrical Bearing Protection Q&A Part 14","description":"In this installment of AEGIS Q&A, we talk about shaft voltage polarity, dusty environments, & inductive cores.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-04 19:03:14","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:44","updated":"2026-11-16 20:16:58","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A Part 14\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A Part 14","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-14\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/pos-neg-300x237-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/59","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=59"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/59\/revisions"}],"predecessor-version":[{"id":10718,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/59\/revisions\/10718"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/1277"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=59"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=59"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=59"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}