{"id":65,"date":"2022-02-08T09:13:00","date_gmt":"2022-02-08T14:13:00","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=65"},"modified":"2026-10-22T15:00:59","modified_gmt":"2026-10-22T19:00:59","slug":"electrical-bearing-protection-qa-part-20","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A \u2013 Part 20"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Q1.\u00a0 How important is a clean environment for the ring\u2019s operation and lifetime?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img decoding=\"async\" class=\"alignright\" alt=\"sawdust-e1596820541560-226x300\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg\" width=\"226\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is a good candidate for internal shaft grounding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1.\u00a0<span>\u00a0<\/span><\/strong>It\u2019s important, but not super-critical.\u00a0 AEGIS<sup>\u00ae<\/sup><span>\u00a0<\/span>Rings\u2019 conductive microfibers are pretty tolerant of contamination.\u00a0 They cut through small amounts of dust and grease.\u00a0 You want to install the ring in whatever location is best \u2013 it can be outside at the drive end, inside the motor, or at the non-drive end, maybe inside the end bell.\u00a0 You can also put an O ring on the shaft and slide it up to SGR.\u00a0 That prevents a lot of contamination.\u00a0 People also add slingers or covers to prevent contaminant ingress.\u00a0 For larger motors, we make the PROSL-R with a rubber gasket.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But we\u2019ve got grounding rings in all kinds of applications \u2013 paper mills, mines, cement milling.\u00a0 Dusty, mucky places.\u00a0 We know of one limestone processor around the Great Lakes with lime dust everywhere, and grounding rings everywhere.\u00a0 And those rings are still working.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The bottom line is you want to keep the rings as clean as you can, but don\u2019t sweat it too much if they get a little dirty.\u00a0 If there\u2019s ever a question of whether they\u2019re still working, test the shaft voltage. We\u2019re here for you<span>\u00a0<\/span>if you ever need help with that.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><img decoding=\"async\" class=\"alignleft\" alt=\"o-ring-300x180\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/o-ring-300x180-1.png\" width=\"300\">Q2.\u00a0 How is the ring grounded\/bonded to the motor frame?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">An AEGIS uKIT with rubber o-ring to protect the conductive microfibers from contamination.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2.\u00a0<span>\u00a0<\/span><\/strong>Just a preliminary bit of jargon:\u00a0 This is really<span>\u00a0<\/span><em>bonding<\/em><span>\u00a0<\/span>we\u2019re talking about.\u00a0 Grounding has a few meanings, with often subtle differences.\u00a0 But electrical bonding always means that two objects are in electrical contact.\u00a0 That is, charge can flow easily from one to the other.\u00a0 In the case of a grounding ring, charge flows from the motor shaft to the ring.\u00a0 The question is, how does that charge get off the ring and onto the motor frame?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Through the mounting hardware (or conductive epoxy).\u00a0 Our basic \u201cclamp-on\u201d shaft grounding rings are held on by clamps bolted to the motor frame.\u00a0 Here, the bonding is through the clamps and screws.\u00a0 Bolt-through rings have screws through them into the motor frame.\u00a0 Fairly obviously, the bonding is through the bolts.\u00a0 With AEGIS uKITs, the bonding is the same but with the addition of mounting brackets.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Many motor repair contractors install press-fit rings.\u00a0 Here, they bore a cavity into the motor frame or bearing retainer ring, and press the grounding ring in.\u00a0 So the bond here is direct metal-metal contact between the ring and the frame.\u00a0 With conductive epoxy mounting, you grind away the paint from the motor frame where the ring will be mounted, so the bond is from the ring, through the epoxy, to the frame.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We should point out that while the mounting bonds the ring to the motor frame, the frame also needs to be bonded back to the VFD.\u00a0 This bond can be through the facility ground.\u00a0 But it\u2019s best to use a<span>\u00a0<\/span>good VFD cable, including symmetric ground wires and shielding (braided or foil).\u00a0 Good cabling makes a big difference to motor grounding.\u00a0 It also helps with electrical noise (EMI\/RFI) in your facility.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3.\u00a0 Can we get away with a higher shaft voltage amplitude with a good choice of bearing grease?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3.\u00a0<span>\u00a0<\/span><\/strong>Not really.\u00a0 Whatever grease you use \u2013 and you should always follow the bearing manufacturer\u2019s recommendation \u2013 you will always end up with a thin film between the bearing rollers and races. Voltage will build up across that film, and arcing will occur without protection.\u00a0 And no matter how good an insulator the grease starts off as, its insulating strength will always go down.\u00a0 That\u2019s because as arcing occurs, you\u2019ll end up with tiny bits of metal blasted off the bearing metal going into the grease.\u00a0 That\u2019s why grease blackens over time.\u00a0 All those metal bits make the grease more conductive, so you have even more arcing occurring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">About twenty years ago, a lot of people\u2019s thinking was that conductive grease was the way to go.\u00a0 The thought was:\u00a0 Let the shaft voltage discharge easily, and less-destructively.\u00a0 But there were all kinds of problems with this.\u00a0 Among other things, it turns out that the conductive particles in this grease were abrasive.\u00a0 You want bearings to stay smooth; you don\u2019t want abrasive powders in your grease.\u00a0 So people would use this grease, and it would work at first, and then a year or two later, the bearings would overheat and fail due to this abrasion.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, &#038; if choice of grease can affect shaft voltage damage.<\/p>\n","protected":false},"author":7,"featured_media":10069,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-65","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, &amp; if choice of grease can affect shaft voltage damage.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A \u2013 Part 20\" \/>\n\t\t<meta property=\"og:description\" content=\"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, &amp; if choice of grease can affect shaft voltage damage.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"226\" \/>\n\t\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2022-02-08T14:13:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:00:59+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A \u2013 Part 20\" \/>\n\t\t<meta name=\"twitter:description\" content=\"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, &amp; if choice of grease can affect shaft voltage damage.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A \\u2013 Part 20\",\"headline\":\"Electrical Bearing Protection Q&#038;A \\u2013 Part 20\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/sawdust-e1596820541560-226x300-1.jpg\",\"width\":226,\"height\":300,\"caption\":\"#image_title\"},\"datePublished\":\"2022-02-08T09:13:00-05:00\",\"dateModified\":\"2026-10-22T15:00:59-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A \\u2013 Part 20\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A \\u2013 Part 20\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/\",\"name\":\"Electrical Bearing Protection Q&A \\u2013 Part 20\",\"description\":\"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, & if choice of grease can affect shaft voltage damage.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/sawdust-e1596820541560-226x300-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#mainImage\",\"width\":226,\"height\":300,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-20\\\/#mainImage\"},\"datePublished\":\"2022-02-08T09:13:00-05:00\",\"dateModified\":\"2026-10-22T15:00:59-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A \u2013 Part 20<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A \u2013 Part 20","description":"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, & if choice of grease can affect shaft voltage damage.","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#article","name":"Electrical Bearing Protection Q&A \u2013 Part 20","headline":"Electrical Bearing Protection Q&#038;A \u2013 Part 20","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg","width":226,"height":300,"caption":"#image_title"},"datePublished":"2022-02-08T09:13:00-05:00","dateModified":"2026-10-22T15:00:59-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#listItem","name":"Electrical Bearing Protection Q&#038;A \u2013 Part 20"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A \u2013 Part 20","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/","name":"Electrical Bearing Protection Q&A \u2013 Part 20","description":"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, & if choice of grease can affect shaft voltage damage.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#mainImage","width":226,"height":300,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/#mainImage"},"datePublished":"2022-02-08T09:13:00-05:00","dateModified":"2026-10-22T15:00:59-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A \u2013 Part 20","og:description":"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, &amp; if choice of grease can affect shaft voltage damage.","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg","og:image:width":226,"og:image:height":300,"article:published_time":"2022-02-08T14:13:00+00:00","article:modified_time":"2026-10-22T19:00:59+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A \u2013 Part 20","twitter:description":"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, &amp; if choice of grease can affect shaft voltage damage.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"4 minutos"},"aioseo_meta_data":{"post_id":"65","title":"Electrical Bearing Protection Q&A \u2013 Part 20","description":"We talk about cleanliness, how AEGIS rings connect electrically to the motor frame, & if choice of grease can affect shaft voltage damage.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:20:37","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:45","updated":"2026-11-16 20:18:32","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A \u2013 Part 20\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A \u2013 Part 20","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-20\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/sawdust-e1596820541560-226x300-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/65","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=65"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/65\/revisions"}],"predecessor-version":[{"id":10709,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/65\/revisions\/10709"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/10069"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=65"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=65"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=65"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}