{"id":77,"date":"2023-01-10T09:15:00","date_gmt":"2023-01-10T14:15:00","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=77"},"modified":"2026-10-22T15:00:52","modified_gmt":"2026-10-22T19:00:52","slug":"electrical-bearing-protection-qa-part-31","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Q1.\u00a0 Are there any widely accepted ways to quantify the degree of electrical damage a bearing has sustained?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1.<\/strong> <span style=\"font-size: 19px;\">You would have to do vibration analysis\u00a0and monitor the spectrum\u00a0over time, as illustrated to the right.\u00a0Vibration analysis can also, of course, detect other types of damage.\u00a0Fluting from electrical bearing damage has a well-known vibrational profile.\u00a0That is, well-known to vibration analysts; less so to non-specialists.\u00a0We have seen webinars by the <a href=\"https:\/\/www.linkedin.com\/company\/mobius-institute\/\" rel=\"noopener\" target=\"_blank\">Mobius Institute<\/a> that talked about fluting and pointed out its characteristics in the vibrational spectrum.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-size: 19px;\">Shaft voltage testing is not good at telling you how much damage has accrued.\u00a0To some extent, you can infer damage based on peak shaft voltage trends.\u00a0If peak shaft voltage decreases over time, we interpret that to mean that bits of metal blasted out of the bearing have made the grease more conductive, so discharge occurs at lower shaft voltage.\u00a0But that is less indicative of the degree of damage than a thorough vibration analysis.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q2.\u00a0In your webinars, you say that, as a rule of thumb, damage may occur above five volts of shaft voltage.\u00a0 Is that peak-to-peak voltage?<img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"VpVSVpp\" height=\"215\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/VpVSVpp.png\" width=\"300\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-weight: normal;\"><span style=\"font-weight: bold;\">A2.<\/span>\u00a0No, that&#8217;s 5V<sub>peak<\/sub>.\u00a0 That would be 10V<sub>pp<\/sub>, which people often prefer because many oscilloscopes report it automatically.\u00a0Below 5V<sub>p<\/sub>, you may still have occasional discharges through the bearing, but they will not be energetic enough to do serious damage over the natural lifetime of the bearing.\u00a0 Discharges of 5V or less might theoretically cause failure eventually, but in practice, the bearing will fail of \u00abnatural causes\u00bb before the electrical damage accumulates enough to cause failure on its own.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-weight: normal;\">It&#8217;s worth pointing out that the energy released when voltage discharges are proportional to the square of the voltage. If you compare damage from different shaft voltage levels, if the voltage is doubled, the energy in the discharge is quadrupled.\u00a0So if 10V does one unit of damage, 20V could do four units of damage, and 5V could only do one quarter.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Q3.\u00a0 Does the shaft voltage change with motor speed?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A3.<span style=\"font-weight: normal;\">\u00a0Yes, but not too significantly.\u00a0The peak shaft voltage will be the same, because it&#8217;s determined by the motor&#8217;s internal capacitances (which don&#8217;t change) and the drive output&#8217;s common mode voltage.\u00a0The common mode voltage won&#8217;t change in <span style=\"text-decoration: underline;\">magnitude<\/span> (height), because its size is determined by the drive&#8217;s bus voltage (which is fixed).\u00a0But it will change <span style=\"text-decoration: underline;\">shape<\/span> with motor speed, and so will the shaft voltage.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Every time an IGBT (switch) in the drive switches on or off, the common mode voltage will step up or down.\u00a0At different speeds, those IGBTs will spend different amounts of time in the On and Off states, and that will determine the shape (but not the height) of the common mode (and shaft) voltage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We aren&#8217;t aware of any smoking-gun evidence that motor speed makes a big difference to how quickly bearings are electrically damaged.\u00a0 We suspect that lower speeds may be somewhat worse for electrical damage than higher speeds, but we don&#8217;t know of any proof, and at any rate, the difference is small.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Shaft Grounding Rings also have a<span>\u00a0<\/span><a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\">2-year extended warranty<\/a><span>\u00a0<\/span>against bearing fluting damage. No other form of shaft grounding offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection,<span>\u00a0<\/span><a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\">sign up for a training<\/a>. We offer monthly live training webinars, and \u2013 pandemic restrictions permitting \u2013 we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.<\/p>\n","protected":false},"author":7,"featured_media":8989,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-77","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Detecting Damage | Electrical Bearing Protection Q&amp;A Part 31\" \/>\n\t\t<meta property=\"og:description\" content=\"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"238\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-01-10T14:15:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:00:52+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Detecting Damage | Electrical Bearing Protection Q&amp;A Part 31\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#article\",\"name\":\"Detecting Damage | Electrical Bearing Protection Q&A Part 31\",\"headline\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Pitting-Discharge-Event630px-300x238-1.jpg\",\"width\":300,\"height\":238,\"caption\":\"#image_title\"},\"datePublished\":\"2023-01-10T09:15:00-05:00\",\"dateModified\":\"2026-10-22T15:00:52-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/\",\"name\":\"Detecting Damage | Electrical Bearing Protection Q&A Part 31\",\"description\":\"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/Pitting-Discharge-Event630px-300x238-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#mainImage\",\"width\":300,\"height\":238,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-31\\\/#mainImage\"},\"datePublished\":\"2023-01-10T09:15:00-05:00\",\"dateModified\":\"2026-10-22T15:00:52-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Detecting Damage | Electrical Bearing Protection Q&amp;A Part 31<\/title>\n\n","aioseo_head_json":{"title":"Detecting Damage | Electrical Bearing Protection Q&A Part 31","description":"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#article","name":"Detecting Damage | Electrical Bearing Protection Q&A Part 31","headline":"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg","width":300,"height":238,"caption":"#image_title"},"datePublished":"2023-01-10T09:15:00-05:00","dateModified":"2026-10-22T15:00:52-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#listItem","name":"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/","name":"Detecting Damage | Electrical Bearing Protection Q&A Part 31","description":"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#mainImage","width":300,"height":238,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/#mainImage"},"datePublished":"2023-01-10T09:15:00-05:00","dateModified":"2026-10-22T15:00:52-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Detecting Damage | Electrical Bearing Protection Q&amp;A Part 31","og:description":"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg","og:image:width":300,"og:image:height":238,"article:published_time":"2023-01-10T14:15:00+00:00","article:modified_time":"2026-10-22T19:00:52+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Detecting Damage | Electrical Bearing Protection Q&amp;A Part 31","twitter:description":"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"3 minutos"},"aioseo_meta_data":{"post_id":"77","title":"Detecting Damage | Electrical Bearing Protection Q&A Part 31","description":"Questions and answers on detecting electrical bearing damage before bearing failure occur, by vibration analysis and shaft voltage measurement.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-04 18:35:13","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:48","updated":"2026-11-16 20:18:32","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A \u2013 Part 31 Detecting Damage\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A &#8211; Part 31 Detecting Damage","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-31\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Pitting-Discharge-Event630px-300x238-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/77","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=77"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/77\/revisions"}],"predecessor-version":[{"id":10689,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/77\/revisions\/10689"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/8989"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=77"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=77"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=77"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}