{"id":81,"date":"2020-11-03T13:55:17","date_gmt":"2020-11-03T18:55:17","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=81"},"modified":"2026-10-22T15:01:06","modified_gmt":"2026-10-22T19:01:06","slug":"electrical-bearing-protection-qa-part-6","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A Part 6"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 6 in a series of questions and answers from our Q&amp;A <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">webinars<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1:\u00a0 Do you need a shaft grounding ring <em>and<\/em> a high frequency bonding strap, or is just the strap enough?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1:<\/strong>\u00a0 You definitely need a grounding ring.\u00a0 You may or may not need a grounding strap, too.\u00a0 Motor and drive manufacturers <a href=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HFGS_Recommendations.pdf\" rel=\"noopener noreferrer\" target=\"_blank\">recommend them<\/a>.\u00a0 Here&#8217;s what&#8217;s going on:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Three phase power off the line is balanced.\u00a0 The voltage in each of the three phases always cancels out; the sum of the three voltages is zero. Power from a VFD is unbalanced.\u00a0 The voltages in each phase do not cancel each other out.\u00a0 So when the power gets to the motor&#8217;s stator windings, there is a net voltage.\u00a0 This net, or common mode, voltage also changes rapidly.\u00a0 When the drive switches a phase on or off, the net voltage changes by hundreds of volts in under a microsecond.\u00a0 Whenever voltage in a line changes rapidly like this, you get high frequency current leaking out through stray capacitances.\u00a0 This stray current has to get back to the drive somehow.\u00a0 We talk about \u00abground\u00bb and grounding, but for our purposes, ground is just a part of the path back to the drive.<img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"aligncenter wp-image-3067\" height=\"313\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png\" width=\"600\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That&#8217;s what this image shows.\u00a0 Rapidly changing voltage in the stator windings makes current leak out onto the rotor and the motor frame.\u00a0 Without shaft grounding, current from the rotor will arc through the bearings to get to the frame and then ground.\u00a0 In the image above, it&#8217;s called <em>rotor current<\/em>, but it&#8217;s more often called shaft current or shaft voltage discharge.\u00a0 If you put an AEGIS ring on the shaft, then this current can get to the frame <em>without<\/em> arcing through the bearing.\u00a0 That&#8217;s what shaft grounding rings are for.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Meanwhile, you have a large amount of current leaking from the windings onto the frame.\u00a0 In the image, it&#8217;s called stator current.\u00a0 This needs to run to ground, too.\u00a0 If the frame&#8217;s ground connection is good, no problem.\u00a0 But if the motor is poorly grounded, this current often ends up jumping from the frame through the bearings to the shaft, then through the coupled equipment&#8217;s bearings, then to ground.\u00a0 This destructive current is called <em>rotor ground current<\/em>.\u00a0 It can kill both the motor&#8217;s bearings <span style=\"text-decoration: underline;\">and<\/span> the equipment&#8217;s bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To clarify the terminology in the image:\u00a0 <em>rotor current<\/em> comes <em>from<\/em> the rotor; <em>stator current<\/em> comes <em>from<\/em> the stator.\u00a0 If the grounding is good, stator current just flows to ground.\u00a0 If the grounding is poor, stator current will instead arc through the bearings as <em>rotor ground current<\/em>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">What a grounding strap does is ensure that current from the frame can go to ground.\u00a0 The strap gives a nice low-resistance path from the motor to the equipment, so stator current flows through it instead of through the bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now, getting to your question:\u00a0 If you <em>only<\/em> have a grounding strap, and no grounding ring, you will prevent rotor ground current from damaging the bearings.\u00a0 But you will still get damage from shaft voltage discharge, unless you also have a grounding ring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2:\u00a0 What&#8217;s the difference between an AEGIS HFGS and a regular braided grounding strap?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2:\u00a0 <\/strong>Any braided grounding strap will do the job.\u00a0 The wider it is, the more surface area it has, and the better it works.\u00a0 The surface area is important because these are high frequency currents, and they travel on the surface of conductors.\u00a0 It&#8217;s called the skin effect.\u00a0 The more surface area a conductor has, the less impedance (resistance) it has to high frequencies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS HFGS are easier to use because you can get them with bolt holes punched into them.\u00a0 You can size them based on NEMA\/IEC frame size, and just attach them through the bolt hole in the motor foot.\u00a0 But otherwise, they&#8217;re equivalent.<a href=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/hfgs-to-cage.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"hfgs-to-cage-disp270x216\" height=\"240\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/hfgs-to-cage-disp270x216.jpg\" width=\"300\"><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3:\u00a0 The grounding strap gets attached to the motor at one end.\u00a0 What is the other end of the strap attached to?<br><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3:\u00a0 <\/strong>Good question.\u00a0 You want to be sure that from motor frame to earth ground you have good conductors with as few connections as possible.\u00a0 Like the I-beam frame of a building:\u00a0 steel is a good conductor.\u00a0 Concrete is not.\u00a0 So ground wires should not terminate at concrete.\u00a0 We&#8217;ve been to plants where they have a grounding mat, which is like a grid of cross-hatched rebar, buried in the ground.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It also helps to use the strap to bond the motor frame to the driven equipment&#8217;s frame.\u00a0 If both the motor and equipment are poorly grounded, this won&#8217;t help current get back to the drive, but it <em>will<\/em> prevent rotor ground current from scorching the bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4: What kind of amperage on a grounding strap is too high?\u00a0 We have a spec of less than 5 amps, and that seems high, even for a 300 hp motor.\u00a0 Could this be phase imbalance, since our machines only use a VFD to start?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A4:<\/strong>\u00a0 The current capacity of a grounding strap depends on its width and thickness.\u00a0 We size ground straps based on motor specs, so the larger the motor, the higher current capacity the strap will have.\u00a0 On a drive, stator ground current comes in pulses.\u00a0 Those pulses range from 20 amps for small motors up to 200 amps for very large ones.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But if you&#8217;re on line power and seeing 5 amps, there&#8217;s something else going on.\u00a0 You shouldn&#8217;t be able to power another piece of equipment with the ground wire.\u00a0 You&#8217;re right that the ground current you see is a symptom of an underlying problem.\u00a0 Whether it&#8217;s phase imbalance or something else, we can&#8217;t say.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Shaft grounding questions &#038; answers: In this installment, all about high frequency grounding straps (HFGS).<\/p>\n","protected":false},"author":7,"featured_media":1198,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-81","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Shaft grounding questions &amp; answers: In this installment, all about high frequency grounding straps (HFGS).\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"es_ES\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A Part 6\" \/>\n\t\t<meta property=\"og:description\" content=\"Shaft grounding questions &amp; answers: In this installment, all about high frequency grounding straps (HFGS).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"890\" \/>\n\t\t<meta property=\"og:image:height\" content=\"464\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-11-03T18:55:17+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:06+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A Part 6\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Shaft grounding questions &amp; answers: In this installment, all about high frequency grounding straps (HFGS).\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura estimado\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A Part 6\",\"headline\":\"Electrical Bearing Protection Q&#038;A Part 6\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/edmrg-i_-ppt.png\",\"width\":890,\"height\":464,\"caption\":\"#image_title\"},\"datePublished\":\"2020-11-03T13:55:17-05:00\",\"dateModified\":\"2026-10-22T15:01:06-04:00\",\"inLanguage\":\"es-ES\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A Part 6\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A Part 6\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/\",\"name\":\"Electrical Bearing Protection Q&A Part 6\",\"description\":\"Shaft grounding questions & answers: In this installment, all about high frequency grounding straps (HFGS).\",\"inLanguage\":\"es-ES\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/edmrg-i_-ppt.png\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#mainImage\",\"width\":890,\"height\":464,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/blog\\\/electrical-bearing-protection-qa-part-6\\\/#mainImage\"},\"datePublished\":\"2020-11-03T13:55:17-05:00\",\"dateModified\":\"2026-10-22T15:01:06-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"es-ES\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/es\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A Part 6<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A Part 6","description":"Shaft grounding questions & answers: In this installment, all about high frequency grounding straps (HFGS).","canonical_url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#article","name":"Electrical Bearing Protection Q&A Part 6","headline":"Electrical Bearing Protection Q&#038;A Part 6","author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png","width":890,"height":464,"caption":"#image_title"},"datePublished":"2020-11-03T13:55:17-05:00","dateModified":"2026-10-22T15:01:06-04:00","inLanguage":"es-ES","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/es\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#listItem","name":"Electrical Bearing Protection Q&#038;A Part 6"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A Part 6","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/es\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/es\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/es\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#webpage","url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/","name":"Electrical Bearing Protection Q&A Part 6","description":"Shaft grounding questions & answers: In this installment, all about high frequency grounding straps (HFGS).","inLanguage":"es-ES","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/es\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png","@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#mainImage","width":890,"height":464,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/#mainImage"},"datePublished":"2020-11-03T13:55:17-05:00","dateModified":"2026-10-22T15:01:06-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/es\/#website","url":"https:\/\/www.est-aegis.com\/es\/","name":"Electro Static Technology","inLanguage":"es-ES","publisher":{"@id":"https:\/\/www.est-aegis.com\/es\/#organization"}}]},"og:locale":"es_ES","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A Part 6","og:description":"Shaft grounding questions &amp; answers: In this installment, all about high frequency grounding straps (HFGS).","og:url":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png","og:image:width":890,"og:image:height":464,"article:published_time":"2020-11-03T18:55:17+00:00","article:modified_time":"2026-10-22T19:01:06+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A Part 6","twitter:description":"Shaft grounding questions &amp; answers: In this installment, all about high frequency grounding straps (HFGS).","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png","twitter:label1":"Escrito por","twitter:data1":"AEGIS","twitter:label2":"Tiempo de lectura estimado","twitter:data2":"5 minutos"},"aioseo_meta_data":{"post_id":"81","title":"Electrical Bearing Protection Q&A Part 6","description":"Shaft grounding questions & answers: In this installment, all about high frequency grounding straps (HFGS).","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:15:37","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:49","updated":"2026-11-16 20:18:33","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A Part 6\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/es\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/es\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A Part 6","link":"https:\/\/www.est-aegis.com\/es\/blog\/electrical-bearing-protection-qa-part-6\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/edmrg-i_-ppt.png","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/81","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/comments?post=81"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/81\/revisions"}],"predecessor-version":[{"id":10730,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/posts\/81\/revisions\/10730"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media\/1198"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/media?parent=81"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/categories?post=81"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/es\/wp-json\/wp\/v2\/tags?post=81"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}