{"id":10155,"date":"2021-10-05T09:15:49","date_gmt":"2021-10-05T13:15:49","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=61"},"modified":"2026-10-22T14:51:48","modified_gmt":"2026-10-22T18:51:48","slug":"electrical-bearing-protection-qa-part-16","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A &#8211; Part 16"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 16 in a series of questions and answers from our Q&amp;A <strong><a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">webinars<\/a><\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1.\u00a0 Can we diagnose the presence of shaft voltage based on vibration analysis?<img loading=\"lazy\" decoding=\"async\" alt=\"\" class=\"alignright size-medium wp-image-3424\" height=\"279\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg\" width=\"300\"><\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A1.\u00a0 You can detect electrical bearing damage with vibration analysis, but only after it&rsquo;s occurred.\u00a0 You need an oscilloscope to measure shaft voltage in some way.\u00a0 The usual way is to capture the shaft voltage waveform to look for discharges with an ordinary oscilloscope.\u00a0 Or you can use a more specialized tool like the <strong>Beppe<\/strong> which automatically detects and counts discharges.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2.\u00a0 How can you diagnose whether a motor bearing needs to be protected, and what would you see on a bearing that failed due to electrical damage?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2.<\/strong>\u00a0 Shaft voltage testing, by whatever means, will show you whether a bearing is at risk.\u00a0 In some cases, you can also use an electrical discharge detector.\u00a0 In our experience though, discharge detectors don&rsquo;t work well with small motors.\u00a0 In either case, the testing is all done online, while the motor is running.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If the bearing has already failed, you will need to cut it, examine the grease, and see what the balls and inside of the raceways look like.\u00a0 In case of electrical damage, the grease will usually be black from charring and contamination with metal particles.\u00a0 And the race will have visible damage ranging from frosting to fluting.\u00a0 Both are easy to see.\u00a0 Frosting shows as a matte band, very distinct against the mirror-smooth finish of the rest of the race.\u00a0 And fluting shows as regular striping occurring in a frosted band.\u00a0 In either case, the rolling elements will typically also be frosted.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3. What kind of oscilloscope do I need to measure shaft voltage?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3.<\/strong>\u00a0 Like TVs or VCRs (remember those?), oscilloscopes all work pretty much the same.\u00a0 The one catch is that you need a scope with at least 100 MHz bandwidth.\u00a0 Shaft voltage buildup, and especially discharge, are fast phenomena.\u00a0 A scope&rsquo;s bandwidth is a measure of its ability to measure high-speed\/high-frequency events.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/scopes-different-1024x427-1.jpg\" alt=\"\" style=\"width:512px\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">The higher the bandwidth, the more accurate at low timescales\/high frequencies.\u00a0 We&rsquo;ve found that 100 MHz is enough.\u00a0 Higher bandwidth is good, but you don&rsquo;t need to go out and buy a 500 MHz scope when 100 MHz is fine.\u00a0 You will need some type of special probe tip.\u00a0 We offer the SVP-TIP-9100 3-pack of probe tips, which fit our own and some Fluke probes.\u00a0 We also offer a 10:1 probe plus tip combo pack, the AEGIS-SVP-510.\u00a0 The probe has a BNC connector so you can use it with any oscilloscope with BNC ports.\u00a0 You can see all of our shaft voltage testing accessories <a href=\"https:\/\/www.est-aegis.com\/product\/mounting-accessories\/shaft-voltage-tester\/\" rel=\"noopener\" target=\"_blank\">here<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.<\/p>\n","protected":false},"author":7,"featured_media":9646,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-10155","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A - Part 16\" \/>\n\t\t<meta property=\"og:description\" content=\"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"279\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-10-05T13:15:49+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T18:51:48+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A - Part 16\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A - Part 16\",\"headline\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 16\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/vibanal-300x279-1.jpg\",\"width\":300,\"height\":279,\"caption\":\"#image_title\"},\"datePublished\":\"2021-10-05T09:15:49-04:00\",\"dateModified\":\"2026-10-22T14:51:48-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Opcional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 16\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A &#8211; Part 16\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/\",\"name\":\"Electrical Bearing Protection Q&A - Part 16\",\"description\":\"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/vibanal-300x279-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#mainImage\",\"width\":300,\"height\":279,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-16\\\/#mainImage\"},\"datePublished\":\"2021-10-05T09:15:49-04:00\",\"dateModified\":\"2026-10-22T14:51:48-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A - Part 16<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A - Part 16","description":"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#article","name":"Electrical Bearing Protection Q&A - Part 16","headline":"Electrical Bearing Protection Q&#038;A &#8211; Part 16","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg","width":300,"height":279,"caption":"#image_title"},"datePublished":"2021-10-05T09:15:49-04:00","dateModified":"2026-10-22T14:51:48-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#webpage"},"articleSection":"Q&amp;A Series, Opcional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#listItem","name":"Electrical Bearing Protection Q&#038;A &#8211; Part 16"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A &#8211; Part 16","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/","name":"Electrical Bearing Protection Q&A - Part 16","description":"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#mainImage","width":300,"height":279,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/#mainImage"},"datePublished":"2021-10-05T09:15:49-04:00","dateModified":"2026-10-22T14:51:48-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A - Part 16","og:description":"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg","og:image:width":300,"og:image:height":279,"article:published_time":"2021-10-05T13:15:49+00:00","article:modified_time":"2026-10-22T18:51:48+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A - Part 16","twitter:description":"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"2 minutes"},"aioseo_meta_data":{"post_id":"10155","title":"Electrical Bearing Protection Q&A - Part 16","description":"Answers to your questions on vibration analysis, detecting electrical bearing damage, and choosing an oscilloscope to measure shaft voltage.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:30:13","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:44","updated":"2026-11-16 21:23:21","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A \u2013 Part 16\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A &#8211; Part 16","link":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-16\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/vibanal-300x279-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10155","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=10155"}],"version-history":[{"count":2,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10155\/revisions"}],"predecessor-version":[{"id":10517,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10155\/revisions\/10517"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/9646"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=10155"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=10155"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=10155"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}