{"id":10166,"date":"2020-08-25T09:51:26","date_gmt":"2020-08-25T13:51:26","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=75"},"modified":"2026-10-22T15:01:08","modified_gmt":"2026-10-22T19:01:08","slug":"electrical-bearing-protection-qa-part-3","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A Part 3"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 3 in a series of questions and answers from our Q&amp;A webinars.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q:\u00a0 If you use insulated bearings without an SGR, where will the current from the shaft go?<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"insulated-bearing\" height=\"250\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing.jpeg\" width=\"250\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong>\u00a0 First off, there are two levels of insulated bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00ab\u00a0Insulated bearings\u00a0\u00bb <em>per se<\/em> have an aluminum oxide coating on the outer or inner ring &#8211; for example, SKF&rsquo;s INSOCOAT bearings.\u00a0 The rolling elements are steel.\u00a0 Their cost is about 3-5 times a standard bearing.\u00a0 The electrical resistance of the aluminum oxide coating is high, from 5 to 150 M\u03a9 (megaohms).\u00a0 But it is still possible to get shaft voltage building up enough to cause arcing through the steel parts of the bearing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There are also <em>hybrid<\/em> or ceramic rolling element bearings.\u00a0 These have steel rings and ceramic balls (rolling elements), and are essentially electrically inert (~ millions of M\u03a9).\u00a0 If you put two ceramic bearings on the motor, then current cannot pass through the bearings, period.\u00a0 One downside is that ceramic bearings and couplings are 7-10 times more expensive than standard bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Back to the question, if it can&rsquo;t get through the motor bearings, then how can the shaft voltage discharge?\u00a0 If the motor is coupled to a fan or a pump, the path of least resistance to that current from the shaft will be <i>through<\/i> the equipment.\u00a0 So the motor bearings will be fine, but the bearings of the coupled equipment will be damaged.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your primary concern is the coupled equipment &#8211; your fans, gearboxes, and pumps &#8211; they&rsquo;re typically 2-3 times more expensive than the motor driving them.\u00a0 If you electrically isolate the motor shaft from the frame, with insulated bearings, the shaft voltage from the VFD will still seek a path to ground, and that path is probably going to go through that expensive coupled equipment.\u00a0 Insulated bearings protect the less-expensive part of the system and leave the more expensive parts vulnerable.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This can be prevented with an electrically insulating ceramic coupling between the motor shaft and the driven equipment.\u00a0 But like ceramic bearings, ceramic couplings are expensive, again 7-10 times the cost of an ordinary steel coupling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is more economical to protect small motors <em>and<\/em> their driven equipment with an AEGIS<sup>\u00ae<\/sup> Shaft Grounding Ring.\u00a0 By bleeding voltage off the shaft, the ring protects both motor and equipment bearings.\u00a0 Motors over 100 hp (75 kW) are prone to high frequency circulating currents, as well as shaft voltage discharge damage.\u00a0 For these larger motors, we recommend one bearing with outer ring insulation to interrupt the circulating current, along with an AEGIS ring to take care of the shaft voltage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So insulated bearings are limited, but they&rsquo;re definitely better than nothing at all.\u00a0 We recommend one of them, in conjunction with a grounding ring, because they&rsquo;re much less expensive, but still protect adequately against circulating currents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q:\u00a0 How do AEGIS rings compare against carbon brushes for shaft grounding?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong>\u00a0 We recently published a <a href=\"\/how-do-shaft-grounding-brushes-compare-with-aegis-rings?hsLang=en-us\" rel=\"noopener\" target=\"_blank\">full blog post<\/a> on this.\u00a0 In brief:\u00a0 Carbon brushes are 100 years old.\u00a0 Nowadays carbon brushes have different composition and holder designs, but they&rsquo;re basically the same technology.\u00a0 AEGIS rings were patented in 2005.\u00a0 Over the past 15 years, they&rsquo;ve become the globally dominant shaft grounding technology.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"AEGIS-Bolt-Through\" height=\"200\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/AEGIS-Bolt-Through.jpg\" width=\"300\"> \u00a0 <img loading=\"lazy\" decoding=\"async\" alt=\"Carbon-Dust-4-1000\" height=\"200\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/Carbon-Dust-4-1000.jpg\" width=\"209\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>All carbon brushes have a spring pushing the carbon block against the motor shaft.\u00a0 Because it&rsquo;s under pressure, the brush wears over time, producing dust.\u00a0 And because of this wear, the brushes require adjustment.\u00a0 In field we often see brushes not even in contact with shaft.\u00a0 So brushes are typically mounted outside the motor frame because of this dust and need for adjustment.\u00a0 The brush must also form a patina to slide properly and with low friction.\u00a0 Over time, patina oxidizes and provides electrical resistance.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Shaft Grounding Rings, on the other hand, use conductive microfibers in contact with the shaft.\u00a0 They&rsquo;re not under pressure, so they don&rsquo;t wear or generate dust appreciably.\u00a0 Given that they don&rsquo;t require adjustment, they can be installed inside motors, and in fact we recommend that.\u00a0 Our lab testing indicates a lifetime of 100,000 hours, which is over 11 years.\u00a0 And AEGIS Shaft Grounding Rings are the only electrical bearing protection product to offer a <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">two-year extended warranty<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q:\u00a0 Does VFD carrier frequency have any effect on the rate of bearing degradation?<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/cmv.png\" alt=\"\" style=\"width:250px\"\/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>A:<\/strong>\u00a0 The higher the carrier frequency, the more damaging.\u00a0 But it&rsquo;s impossible to dial it down low enough to eliminate EDM.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EDM is caused by high shaft voltage.\u00a0 The size of the shaft voltage is controlled by the size of the common mode voltage (CMV).\u00a0 The larger the CMV, the larger the shaft voltage.\u00a0 The CMV&rsquo;s maximum (see figure) is primarily determined by the dc bus voltage, although higher carrier frequencies can increase it by reflected wave effects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But whatever the carrier frequency, if the CMV and shaft voltage get high enough, EDM damage <em>will<\/em> occur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>More questions &#038; answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.<\/p>\n","protected":false},"author":7,"featured_media":9357,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-10166","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"More questions &amp; answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A Part 3\" \/>\n\t\t<meta property=\"og:description\" content=\"More questions &amp; answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"360\" \/>\n\t\t<meta property=\"og:image:height\" content=\"360\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-08-25T13:51:26+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:08+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A Part 3\" \/>\n\t\t<meta name=\"twitter:description\" content=\"More questions &amp; answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A Part 3\",\"headline\":\"Electrical Bearing Protection Q&#038;A Part 3\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/insulated-bearing-2.jpeg\",\"width\":360,\"height\":360,\"caption\":\"#image_title\"},\"datePublished\":\"2020-08-25T09:51:26-04:00\",\"dateModified\":\"2026-10-22T15:01:08-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A Part 3\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A Part 3\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/\",\"name\":\"Electrical Bearing Protection Q&A Part 3\",\"description\":\"More questions & answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/insulated-bearing-2.jpeg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#mainImage\",\"width\":360,\"height\":360,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-3\\\/#mainImage\"},\"datePublished\":\"2020-08-25T09:51:26-04:00\",\"dateModified\":\"2026-10-22T15:01:08-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A Part 3<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A Part 3","description":"More questions & answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#article","name":"Electrical Bearing Protection Q&A Part 3","headline":"Electrical Bearing Protection Q&#038;A Part 3","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg","width":360,"height":360,"caption":"#image_title"},"datePublished":"2020-08-25T09:51:26-04:00","dateModified":"2026-10-22T15:01:08-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#listItem","name":"Electrical Bearing Protection Q&#038;A Part 3"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A Part 3","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/","name":"Electrical Bearing Protection Q&A Part 3","description":"More questions & answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#mainImage","width":360,"height":360,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/#mainImage"},"datePublished":"2020-08-25T09:51:26-04:00","dateModified":"2026-10-22T15:01:08-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A Part 3","og:description":"More questions &amp; answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg","og:image:width":360,"og:image:height":360,"article:published_time":"2020-08-25T13:51:26+00:00","article:modified_time":"2026-10-22T19:01:08+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A Part 3","twitter:description":"More questions &amp; answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"4 minutes"},"aioseo_meta_data":{"post_id":"10166","title":"Electrical Bearing Protection Q&A Part 3","description":"More questions & answers from our live webinars. In this installation: insulated bearings, carbon brushes, and carrier frequency.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:23:48","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:47","updated":"2026-11-16 21:27:11","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A Part 3\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A Part 3","link":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-3\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/insulated-bearing-2.jpeg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10166","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=10166"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10166\/revisions"}],"predecessor-version":[{"id":10735,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10166\/revisions\/10735"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/9357"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=10166"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=10166"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=10166"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}