{"id":10187,"date":"2023-08-22T09:00:00","date_gmt":"2023-08-22T13:00:00","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=153"},"modified":"2026-10-22T15:00:48","modified_gmt":"2026-10-22T19:00:48","slug":"pumping-systems-on-vfd-need-bearing-protection","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/","title":{"rendered":"Pumping Systems on VFD Need Bearing Protection"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"blueash-21\" height=\"225\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21.jpg\" width=\"300\">In most pump applications, running the pump at full speed is not always necessary.\u00a0 Flow rate has traditionally been decreased with flow control valves, but this has disadvantages.\u00a0 Nowadays, the flow is often controlled by running the pump\u2019s motor on a variable frequency drive (VFD).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Besides well-controlled flow rates, VFDs offer:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 Energy savings (from reduced motor speeds)<br>\u2022 Improved seal and impeller life and reduced vibration and noise (from reduced pressure)<br>\u2022 Greatly reduced water hammer (from smooth acceleration and deceleration)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">But VFDs have their own downsides.\u00a0 One big problem is that they create stray voltage on the motor shaft.\u00a0 This shaft voltage can cause electrical damage to motor and pump bearings by discharging (arcing) through them.\u00a0 This electrical damage accrues over time, causing premature bearing failure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The solution is to electrically bond the shaft to the motor frame with a <a href=\"https:\/\/www.est-aegis.com\/\" rel=\"noopener\" target=\"_blank\">shaft grounding device<\/a>.\u00a0 This gives charge on the shaft a low-resistance path to ground, so current flows through the grounding device instead of arcing through the bearings.\u00a0 (Large motors, over 100 hp\/75 kW also require one insulated bearing to prevent circulating VFD-induced currents.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS<sup>\u00ae<\/sup> Shaft Grounding Rings are the most reliable form of shaft grounding available.\u00a0 AEGIS rings can be installed on existing motors, and several manufacturers also offer motors with AEGIS rings factory-installed, including vertical hollowshaft, severe duty, and even explosion-proof models.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about the problem of VFD-induced bearing currents and the solution using AEGIS rings, see these <a href=\"https:\/\/www.est-aegis.com\/resources\/case-studies\/\" rel=\"noopener\" target=\"_blank\">case studies<\/a> and <a href=\"https:\/\/www.est-aegis.com\/bearing-protection\/best-practices-and-installation\/\" rel=\"noopener\" target=\"_blank\">best practices<\/a>, or see the AEGIS <a href=\"https:\/\/www.youtube.com\/channel\/UCLbnVQas0tkhxFtH1bgc9fw\" rel=\"noopener noreferrer\" target=\"_blank\">Youtube channel<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">* <em>Image: AEGIS rings being installed on pump motors at Blue Ash Recreation Facility in Blue Ash, OH<\/em><\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.<\/p>\n","protected":false},"author":7,"featured_media":1173,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1064],"tags":[],"class_list":["post-10187","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications-and-industries"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How to Protect Pumping Systems on VFD\" \/>\n\t\t<meta property=\"og:description\" content=\"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"225\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-08-22T13:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:00:48+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How to Protect Pumping Systems on VFD\" \/>\n\t\t<meta name=\"twitter:description\" content=\"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#article\",\"name\":\"How to Protect Pumping Systems on VFD\",\"headline\":\"Pumping Systems on VFD Need Bearing Protection\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/blueash-21-300x225-1.jpg\",\"width\":300,\"height\":225,\"caption\":\"#image_title\"},\"datePublished\":\"2023-08-22T09:00:00-04:00\",\"dateModified\":\"2026-10-22T15:00:48-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#webpage\"},\"articleSection\":\"Applications &amp; Industries, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"position\":2,\"name\":\"Applications &amp; Industries\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#listItem\",\"name\":\"Pumping Systems on VFD Need Bearing Protection\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#listItem\",\"position\":3,\"name\":\"Pumping Systems on VFD Need Bearing Protection\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/\",\"name\":\"How to Protect Pumping Systems on VFD\",\"description\":\"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/blueash-21-300x225-1.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#mainImage\",\"width\":300,\"height\":225,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/pumping-systems-on-vfd-need-bearing-protection\\\/#mainImage\"},\"datePublished\":\"2023-08-22T09:00:00-04:00\",\"dateModified\":\"2026-10-22T15:00:48-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>How to Protect Pumping Systems on VFD<\/title>\n\n","aioseo_head_json":{"title":"How to Protect Pumping Systems on VFD","description":"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#article","name":"How to Protect Pumping Systems on VFD","headline":"Pumping Systems on VFD Need Bearing Protection","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg","width":300,"height":225,"caption":"#image_title"},"datePublished":"2023-08-22T09:00:00-04:00","dateModified":"2026-10-22T15:00:48-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#webpage"},"articleSection":"Applications &amp; Industries, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","position":2,"name":"Applications &amp; Industries","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#listItem","name":"Pumping Systems on VFD Need Bearing Protection"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#listItem","position":3,"name":"Pumping Systems on VFD Need Bearing Protection","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/","name":"How to Protect Pumping Systems on VFD","description":"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#mainImage","width":300,"height":225,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/#mainImage"},"datePublished":"2023-08-22T09:00:00-04:00","dateModified":"2026-10-22T15:00:48-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"How to Protect Pumping Systems on VFD","og:description":"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg","og:image:width":300,"og:image:height":225,"article:published_time":"2023-08-22T13:00:00+00:00","article:modified_time":"2026-10-22T19:00:48+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"How to Protect Pumping Systems on VFD","twitter:description":"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"2 minutes"},"aioseo_meta_data":{"post_id":"10187","title":"How to Protect Pumping Systems on VFD","description":"When pump motors are run by variable frequency drives, their bearings are at risk of electrical bearing damage. Here is how to protect them.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-04 18:53:48","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:14:07","updated":"2026-11-16 21:30:05","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/\" title=\"Applications &amp; Industries\">Applications &amp; Industries<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tPumping Systems on VFD Need Bearing Protection\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Applications &amp; Industries","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/"},{"label":"Pumping Systems on VFD Need Bearing Protection","link":"https:\/\/www.est-aegis.com\/fr\/blog\/pumping-systems-on-vfd-need-bearing-protection\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/blueash-21-300x225-1.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10187","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=10187"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10187\/revisions"}],"predecessor-version":[{"id":10676,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/10187\/revisions\/10676"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/1173"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=10187"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=10187"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=10187"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}