{"id":105,"date":"2018-07-11T11:10:21","date_gmt":"2018-07-11T15:10:21","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=105"},"modified":"2026-10-22T15:01:17","modified_gmt":"2026-10-22T19:01:17","slug":"how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/","title":{"rendered":"How NOT to Kill an Electric Motor on a Variable Frequency Drive"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/motioncontroltips.com\" rel=\"noopener\" target=\"_blank\">Motion Control Tips<\/a> recently published a tongue-in-cheek article called \u00ab\u00a0<a href=\"https:\/\/www.motioncontroltips.com\/how-to-kill-your-favorite-variable-frequency-drive\/\" rel=\"noopener\" target=\"_blank\">How to kill your favorite variable frequency drive<\/a>.\u00a0\u00bb\u00a0 (You read that right.)\u00a0 It has a lot of good suggestions of things <span style=\"text-decoration: underline;\">not<\/span> to do if you want your drive to live, written in a fun-to-read facetious style.\u00a0 Our favorite:\u00a0 letting quarters, washers, or other small conductive objects fall through the vents on top of the VFD, where they can short out the DC bus.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"lol-washer+vfd\" height=\"225\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd.png\" width=\"300\">One thing that was beyond the scope of that article was the motor at the far end of the drive-motor system.\u00a0 Which begs the question:\u00a0 Why keep a VFD alive if the motor it drives is broken?\u00a0 So let&rsquo;s talk here about a few of the things you can do to keep your motors in good shape so your still-living VFDs will have something to control.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">1.\u00a0 Winding Insulation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Make sure any VFD-fed motor has <a href=\"https:\/\/www.csemag.com\/search\/search-single-display\/vfds-and-motors-making-the-right-match\" rel=\"noopener\" target=\"_blank\">inverter-duty<\/a> insulation.\u00a0 Otherwise, the winding insulation is likely to fail.\u00a0 Briefly, the voltage output of the VFD changes very rapidly.\u00a0 When that voltage gets to the motor&rsquo;s stator windings, its fast change leads to large voltages between adjacent turns in the winding.\u00a0 If the insulation is not inverter-duty, it can break down and lead to winding failure, requiring motor repair or replacement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">While some motors, fed by some inverters, in some situations, <em>can<\/em> get by with lower-grade winding insulation, it&rsquo;s really not worth the risk.\u00a0 In the likely event that the motor fails and you need to replace or rewind the motor, you&rsquo;re likely to lose more than you stand to save.\u00a0 Don&rsquo;t be penny-wise and pound-foolish.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2.\u00a0 Shaft Grounding<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">All motors run by VFDs develop a capacitive voltage on the shaft.\u00a0 If there&rsquo;s no better path to ground, that voltage may discharge through the bearings, causing cumulative damage and eventually <a href=\"https:\/\/www.est-aegis.com\/bearing-protection\/fluting-and-bearing-inspection\/\" rel=\"noopener\" target=\"_blank\">premature failure<\/a>.\u00a0 The best way to get rid of capacitive shaft voltage is to ground the shaft, giving voltage a low-resistance path to ground, and keeping it from arcing through the bearings.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The best form of shaft grounding is the <a href=\"https:\/\/www.est-aegis.com\/product\/sgr\/\" rel=\"noopener\" target=\"_blank\">AEGIS Shaft Grounding Ring<\/a>, which is available as a retrofit or factory-installed inside <a href=\"https:\/\/www.est-aegis.com\/where-to-buy\/oems-with-aegis\/\" rel=\"noopener\" target=\"_blank\">many leading motor brands<\/a>.\u00a0 AEGIS Rings are the only form of shaft grounding that offers a <a href=\"https:\/\/youtu.be\/qnA2rdTqsg8\" rel=\"noopener\" target=\"_blank\">two year extended warranty against bearing fluting damage<\/a>.\u00a0 For motors with AEGIS factory-installed, this warranty is <em>in addition to<\/em> the manufacturer&rsquo;s warranty.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3.\u00a0 Bearing Insulation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Motors over 100 HP\/75 kW are susceptible to bearing damage from <a href=\"https:\/\/www.est-aegis.com\/bearing-protection\/shaft-voltage-and-bearing-currents\/\" rel=\"noopener\" target=\"_blank\">high-frequency circulating currents<\/a> (in addition to shaft voltage discharge).\u00a0 Installing one insulated bearing suffices to interrupt these circulating currents.\u00a0 An AEGIS Ring is still necessary, at the uninsulated end, to protect from the shaft voltage that is still present.\u00a0 (Insulating both bearings is also fine, but shaft grounding is still recommended to protect the driven equipment from shaft voltage discharge.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Shaft Grounding Rings also have a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\">2-year extended warranty<\/a>\u00a0against bearing fluting damage. No other form of shaft grounding offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection &#8211; for motors and generators &#8211;\u00a0<a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\">sign up for a training<\/a>. We offer monthly live training webinars, and we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.<\/p>\n","protected":false},"author":7,"featured_media":9391,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1065],"tags":[],"class_list":["post-105","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-bearing-damage-basics"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\" \/>\n\t\t<meta property=\"og:description\" content=\"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"225\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2018-07-11T15:10:21+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:17+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\" \/>\n\t\t<meta name=\"twitter:description\" content=\"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#article\",\"name\":\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\",\"headline\":\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/lol-washervfd-small-300x225-1.png\",\"width\":300,\"height\":225,\"caption\":\"#image_title\"},\"datePublished\":\"2018-07-11T11:10:21-04:00\",\"dateModified\":\"2026-10-22T15:01:17-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#webpage\"},\"articleSection\":\"Bearing Damage Basics, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"name\":\"Bearing Damage Basics\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"position\":2,\"name\":\"Bearing Damage Basics\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/bearing-damage-basics\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#listItem\",\"name\":\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#listItem\",\"position\":3,\"name\":\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/bearing-damage-basics\\\/#listItem\",\"name\":\"Bearing Damage Basics\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/\",\"name\":\"How NOT to Kill an Electric Motor on a Variable Frequency Drive\",\"description\":\"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/lol-washervfd-small-300x225-1.png\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#mainImage\",\"width\":300,\"height\":225,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\\\/#mainImage\"},\"datePublished\":\"2018-07-11T11:10:21-04:00\",\"dateModified\":\"2026-10-22T15:01:17-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>How NOT to Kill an Electric Motor on a Variable Frequency Drive<\/title>\n\n","aioseo_head_json":{"title":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","description":"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#article","name":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","headline":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png","width":300,"height":225,"caption":"#image_title"},"datePublished":"2018-07-11T11:10:21-04:00","dateModified":"2026-10-22T15:01:17-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#webpage"},"articleSection":"Bearing Damage Basics, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/bearing-damage-basics\/#listItem","name":"Bearing Damage Basics"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/bearing-damage-basics\/#listItem","position":2,"name":"Bearing Damage Basics","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/bearing-damage-basics\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#listItem","name":"How NOT to Kill an Electric Motor on a Variable Frequency Drive"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#listItem","position":3,"name":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/bearing-damage-basics\/#listItem","name":"Bearing Damage Basics"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/","name":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","description":"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#mainImage","width":300,"height":225,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/#mainImage"},"datePublished":"2018-07-11T11:10:21-04:00","dateModified":"2026-10-22T15:01:17-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","og:description":"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png","og:image:width":300,"og:image:height":225,"article:published_time":"2018-07-11T15:10:21+00:00","article:modified_time":"2026-10-22T19:01:17+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","twitter:description":"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"3 minutes"},"aioseo_meta_data":{"post_id":"105","title":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","description":"These three tips will help you run motors on variable frequency drives reliably, without failures due to electrical damage in the windings or bearings.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:46:07","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:55","updated":"2026-11-16 20:21:44","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/bearing-damage-basics\/\" title=\"Bearing Damage Basics\">Bearing Damage Basics<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tHow NOT to Kill an Electric Motor on a Variable Frequency Drive\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Bearing Damage Basics","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/bearing-damage-basics\/"},{"label":"How NOT to Kill an Electric Motor on a Variable Frequency Drive","link":"https:\/\/www.est-aegis.com\/fr\/blog\/how-not-to-kill-an-electric-motor-on-a-variable-frequency-drive\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/lol-washervfd-small-300x225-1.png","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=105"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/105\/revisions"}],"predecessor-version":[{"id":10758,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/105\/revisions\/10758"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/9391"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}