{"id":162,"date":"2013-01-03T16:39:31","date_gmt":"2013-01-03T21:39:31","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=162"},"modified":"2026-10-22T14:52:25","modified_gmt":"2026-10-22T18:52:25","slug":"shaft-grounding-for-inverter-driven-severe-duty-motors","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/","title":{"rendered":"Shaft Grounding for Inverter-Driven Severe-Duty Motors"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" alt=\"Garlock SGi\u2122 with AEGIS\u2122 SGR inside\" class=\"alignright size-full wp-image-23\" height=\"160\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg\" width=\"200\">The use of variable-frequency drives (VFDs) to control AC motors has increased dramatically in recent years. In addition to their low operating cost and high performance, they save energy. Today, the challenge facing system designers and engineers is to minimize damage to AC motors from shaft current. From its first minute of operation, a VFD induces destructive voltages that build up on the motor shaft until they find discharge paths to the frame (ground). In most cases, the motor bearings present the path of least resistance. Once voltage is sufficient to overcome the resistance of the oil film layer in the bearing, shaft current discharges, causing electrical discharge machining (EDM) pits and fusion craters in the race wall and ball bearings. This phenomenon continues until the bearings become so severely pitted that fluting, excessive noise, and failure occur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mitigation of this damage is possible through various strategies. Some are narrow in application, and<br> most are costly. Many are not technically feasible. However, a new technology employs a circumferential ring of conductive microfibers to discharge harmful currents and provide a low-cost solution to the problem.<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Shaft Grounding for Inverter-Driven Severe-Duty Motors<\/p>\n","protected":false},"author":7,"featured_media":8825,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1064],"tags":[],"class_list":["post-162","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications-and-industries"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\" \/>\n\t\t<meta property=\"og:description\" content=\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"200\" \/>\n\t\t<meta property=\"og:image:height\" content=\"160\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2013-01-03T21:39:31+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T18:52:25+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#article\",\"name\":\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\",\"headline\":\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/HomeGarlock.jpg\",\"width\":200,\"height\":160,\"caption\":\"#image_title\"},\"datePublished\":\"2013-01-03T16:39:31-05:00\",\"dateModified\":\"2026-10-22T14:52:25-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#webpage\"},\"articleSection\":\"Applications &amp; Industries, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"position\":2,\"name\":\"Applications &amp; Industries\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#listItem\",\"name\":\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#listItem\",\"position\":3,\"name\":\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/\",\"name\":\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\",\"description\":\"Shaft Grounding for Inverter-Driven Severe-Duty Motors\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/HomeGarlock.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#mainImage\",\"width\":200,\"height\":160,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/shaft-grounding-for-inverter-driven-severe-duty-motors\\\/#mainImage\"},\"datePublished\":\"2013-01-03T16:39:31-05:00\",\"dateModified\":\"2026-10-22T14:52:25-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Shaft Grounding for Inverter-Driven Severe-Duty Motors<\/title>\n\n","aioseo_head_json":{"title":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","description":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#article","name":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","headline":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg","width":200,"height":160,"caption":"#image_title"},"datePublished":"2013-01-03T16:39:31-05:00","dateModified":"2026-10-22T14:52:25-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#webpage"},"articleSection":"Applications &amp; Industries, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","position":2,"name":"Applications &amp; Industries","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#listItem","name":"Shaft Grounding for Inverter-Driven Severe-Duty Motors"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#listItem","position":3,"name":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/","name":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","description":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#mainImage","width":200,"height":160,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/#mainImage"},"datePublished":"2013-01-03T16:39:31-05:00","dateModified":"2026-10-22T14:52:25-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","og:description":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg","og:image:width":200,"og:image:height":160,"article:published_time":"2013-01-03T21:39:31+00:00","article:modified_time":"2026-10-22T18:52:25+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","twitter:description":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"1 minute"},"aioseo_meta_data":{"post_id":"162","title":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","description":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:34:18","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:14:09","updated":"2026-11-16 20:28:04","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/\" title=\"Applications &amp; Industries\">Applications &amp; Industries<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tShaft Grounding for Inverter-Driven Severe-Duty Motors\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Applications &amp; Industries","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/"},{"label":"Shaft Grounding for Inverter-Driven Severe-Duty Motors","link":"https:\/\/www.est-aegis.com\/fr\/blog\/shaft-grounding-for-inverter-driven-severe-duty-motors\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/HomeGarlock.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=162"}],"version-history":[{"count":2,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/162\/revisions"}],"predecessor-version":[{"id":10630,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/162\/revisions\/10630"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/8825"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=162"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=162"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}