{"id":34,"date":"2023-06-01T10:00:00","date_gmt":"2023-06-01T14:00:00","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=34"},"modified":"2026-10-22T15:00:49","modified_gmt":"2026-10-22T19:00:49","slug":"changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/","title":{"rendered":"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><span style=\"font-size: 18px;\">Shaft grounding for VFD-fed electric motors has largely been disallowed in \u00ab\u00a0Classified\u00a0\u00bb environments where there&rsquo;s a risk of potentially explosive vapor being ignited. Consequently, many of these motors have been at risk of premature bearing failure due to electrical bearing damage caused by the drive.<\/span> <img decoding=\"async\" class=\"alignright\" alt=\"motor-ammonia_dreamstime_s_207228746\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg\" width=\"425\"> <br><span style=\"font-size: 18px;\"><\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Use of Shaft Grounding Rings in Explosion-Proof Motors<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-size: 18px;\">AEGIS<sup>\u00ae<\/sup> Shaft Grounding Rings have been allowed for years in explosion-proof motors when installed according to UL-approved procedures. <a href=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/UL_Approved_for_AEGIS.pdf\" rel=\"noopener\" target=\"_blank\">Dozens of motor repair companies<\/a> in the US are qualified to make these installations. Additionally, manufacturers like US Motors (Nidec), WEG Electric, Marathon (WEG), and Baldor (ABB) offer XP motors with AEGIS rings factory-installed. XP motors, though, are usually only used in Class I, Division 1 (Zone 1) areas. In Class I, Div. 2 (Zone 2) areas, where the risk of ignition is lower, IEEE Standard 841 motors are usually used. But until recently, 841 standard motors could not use shaft grounding devices, which are considered sparking devices.<\/span><span style=\"font-size: 18px;\"><\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><br>Recent Standard and Code Changes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><span style=\"font-size: 18px;\">This began to change with the 2017 edition of the <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" rel=\"noopener\" target=\"_blank\">National Electrical Code<\/a> (NEC; NFPA 70).\u00a0 NEC-2017 allowed shaft bonding (grounding) devices in Class I Div 2 locations, provided \u00ab\u00a0the potential discharge energy is determined to be nonincendive for the application.\u00a0\u00bb In other words, any potential sparks must not have enough energy to ignite the gases present. The 2018 <a href=\"https:\/\/promo.csagroup.org\/2021-cec-packages\" rel=\"noopener\" target=\"_blank\">Canadian Electrical Code<\/a> contained a similar change.<\/span><br><br><span style=\"font-size: 18px;\">After these changes, the next revision of <a href=\"https:\/\/standards.ieee.org\/ieee\/841\/10131\/\" rel=\"noopener\" target=\"_blank\">IEEE Std 841<\/a> allowed shaft grounding in 841-compliant motors. This is good news, and not only for users of motors in hazardous areas. 841 motors are used outside of hazardous areas, too. They are built tough enough to endure hazardous areas, and their protective features contribute to a longer life expectancy than less robust motors. <\/span><span style=\"font-size: 18px;\">So many motor use them by default.\u00a0 <\/span><br><br><span style=\"font-size: 18px;\">In hazardous areas, the task still remains to calculate the discharge energy. This task got easier in 2021 with the release of <a href=\"https:\/\/standards.ieee.org\/ieee\/1349\/10559\/\" rel=\"noopener\" target=\"_blank\">IEE Std 1349-2021<\/a>. The Working Group for this standard also produced a spreadsheet to facilitate calculating the maximum discharge energy based on details of the motor and drive. This spreadsheet is available for free download at the Standard&rsquo;s webpage (in the Additional Resources section). Although some users complete the calculations themselves, most of the required values are best obtained from the motor and drive manufacturers.<\/span><span style=\"font-size: 18px;\"><img decoding=\"async\" class=\"alignright\" alt=\"results\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/results.png\" width=\"425\"><\/span><br><br><span style=\"font-size: 18px;\">Practically speaking, shaft grounding will usually be permissible in 841 motors in most applications, <span style=\"text-decoration: underline;\">except<\/span> when hydrogen (H<sub>2<\/sub>) or acetylene (C<sub>2<\/sub>H<sub>2<\/sub>) gases are present.<\/span><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a more detailed review, see our\u00a0<a href=\"https:\/\/info.est-aegis.com\/technical-codes-and-ieee-841-standards?hsLang=en-us\" rel=\"noopener\" style=\"text-decoration: underline;\"><span style=\"font-weight: bold;\">Technical Bulletin<\/span><\/a>.<br><br><span style=\"font-size: 18px; font-weight: bold;\">This is a lot of information, so to summarize:<\/span><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><span style=\"font-size: 18px;\">IEEE Std 841-compliant motors can now have shaft grounding rings installed in non-classified areas.<\/span><\/li>\n\n\n<li><span style=\"font-size: 18px;\">In classified areas, the maximum possible discharge energy must be calculated and ensured to be less than the minimum ignition energy of any potential explosive vapors in the area.<\/span><\/li>\n\n\n<li><span style=\"font-size: 18px;\">Users can perform these calculations with input or help from the motor and drive manufacturers.<\/span><\/li>\n\n\n<li><span style=\"font-size: 18px;\">Shaft grounding will allow for 841 motors in most situations.<\/span><\/li>\n\n\n<li><span style=\"font-size: 18px;\">In cases where shaft grounding cannot be used with 841 motors, explosion-proof\u00a0motors with AEGIS are still an option.<\/span><span style=\"font-size: 18px;\"><\/span><span style=\"font-size: 18px;\"><\/span><\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Partnering with Electro Static Technology<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings offer a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage, in or out of hazardous locations.\u00a0 No other shaft grounding device manufacturer offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>.\u00a0 We offer monthly live training webinars, and we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.<\/p>\n","protected":false},"author":7,"featured_media":9973,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1064],"tags":[],"class_list":["post-34","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications-and-industries"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations\" \/>\n\t\t<meta property=\"og:description\" content=\"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2023-06-01T14:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:00:49+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#article\",\"name\":\"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations\",\"headline\":\"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/motor-ammonia_dreamstime_s_207228746.jpg\",\"width\":800,\"height\":533,\"caption\":\"#image_title\"},\"datePublished\":\"2023-06-01T10:00:00-04:00\",\"dateModified\":\"2026-10-22T15:00:49-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#webpage\"},\"articleSection\":\"Applications &amp; Industries, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"position\":2,\"name\":\"Applications &amp; Industries\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#listItem\",\"name\":\"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#listItem\",\"position\":3,\"name\":\"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/applications-and-industries\\\/#listItem\",\"name\":\"Applications &amp; Industries\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/\",\"name\":\"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations\",\"description\":\"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/motor-ammonia_dreamstime_s_207228746.jpg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#mainImage\",\"width\":800,\"height\":533,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\\\/#mainImage\"},\"datePublished\":\"2023-06-01T10:00:00-04:00\",\"dateModified\":\"2026-10-22T15:00:49-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations<\/title>\n\n","aioseo_head_json":{"title":"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations","description":"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#article","name":"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations","headline":"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg","width":800,"height":533,"caption":"#image_title"},"datePublished":"2023-06-01T10:00:00-04:00","dateModified":"2026-10-22T15:00:49-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#webpage"},"articleSection":"Applications &amp; Industries, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","position":2,"name":"Applications &amp; Industries","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#listItem","name":"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#listItem","position":3,"name":"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/#listItem","name":"Applications &amp; Industries"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/","name":"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations","description":"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#mainImage","width":800,"height":533,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/#mainImage"},"datePublished":"2023-06-01T10:00:00-04:00","dateModified":"2026-10-22T15:00:49-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations","og:description":"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg","og:image:width":800,"og:image:height":533,"article:published_time":"2023-06-01T14:00:00+00:00","article:modified_time":"2026-10-22T19:00:49+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations","twitter:description":"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"3 minutes"},"aioseo_meta_data":{"post_id":"34","title":"Standards for Shaft Grounding IEEE-841 Motors and Hazardous Locations","description":"Recent code and standard changes allow IEEE-841 motors to use shaft grounding. In hazardous areas, calculations must be done first. Get the details here.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-10-28 18:32:28","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:37","updated":"2026-11-16 20:13:47","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/\" title=\"Applications &amp; Industries\">Applications &amp; Industries<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tChanging Standards: Shaft Grounding in IEEE-841 Motors &amp; Hazardous Locations\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Applications &amp; Industries","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/applications-and-industries\/"},{"label":"Changing Standards: Shaft Grounding in IEEE-841 Motors &#038; Hazardous Locations","link":"https:\/\/www.est-aegis.com\/fr\/blog\/changing-standards-shaft-grounding-in-ieee-841-motors-hazardous-locations\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/motor-ammonia_dreamstime_s_207228746.jpg","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/34","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=34"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/34\/revisions"}],"predecessor-version":[{"id":10680,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/34\/revisions\/10680"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/9973"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=34"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=34"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=34"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}