{"id":80,"date":"2020-10-07T10:56:33","date_gmt":"2020-10-07T14:56:33","guid":{"rendered":"https:\/\/www.est-aegis.com\/?p=80"},"modified":"2026-10-22T15:01:07","modified_gmt":"2026-10-22T19:01:07","slug":"electrical-bearing-protection-qa-part-5","status":"publish","type":"post","link":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/","title":{"rendered":"Electrical Bearing Protection Q&#038;A Part 5"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Part 5 in a series of questions and answers from our Q&amp;A <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">webinars<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q1:\u00a0 What kind of instrument do you need to test for shaft voltage?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A1:\u00a0 <\/strong>You need an ocilloscope with at least 100 MHz of bandwidth.\u00a0 Any brand is fine, as long as it&rsquo;s got the bandwidth.\u00a0 Sad to say, you can NOT use a multimeter or ordinary voltmeter.\u00a0 Shaft voltage<img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"tester-glam\" height=\"211\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam.jpg\" width=\"300\"> is high frequency, &amp; voltmeters just don&rsquo;t have fast enough response time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fluke is a great brand, and their <a href=\"https:\/\/www.fluke.com\/en-us\/product\/electrical-testing\/portable-oscilloscopes\/mda-500-series\" rel=\"noopener noreferrer\" target=\"_blank\">MDA-550<\/a> includes everything you need to test for shaft voltage.\u00a0 But they are expensive.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Our <a href=\"https:\/\/www.est-aegis.com\/product\/mounting-accessories\/shaft-voltage-tester\/\" rel=\"noopener\" target=\"_blank\">AEGIS Shaft Voltage Tester<\/a> may not have all of the bells and whistles, but it does the job.\u00a0 One very nice feature ours has is that you can save a reading just by pressing and holding one button.\u00a0 Usually you have to click through a few screens to record a reading.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q2:\u00a0 We have a three foot diameter fan with a grounding ring at the fan housing.\u00a0 Does this offer any protection to the 250 hp motor that drives it?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A2:\u00a0 <\/strong>Absolutely.\u00a0 But at 250 hp, the motor is also liable to have circulating currents.\u00a0 You really want an insulated or a ceramic bearing to prevent those.\u00a0 Of course it can be hard to change the bearing on an installed motor.\u00a0 So you can also try common mode cores.\u00a0 Those will at least reduce circulating currents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q3:\u00a0 Does a motor on VFD running at constant speed have fewer problems than one with constantly varying speed?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A3:<\/strong>\u00a0 It may.\u00a0 Ultimately, you need to check the shaft voltage.\u00a0 We&rsquo;ve seen installations that are OK running at constant speed, but we&rsquo;ve seen plenty where they did have bearing discharge.\u00a0 When in doubt:\u00a0 Test.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Q4:\u00a0 Can you put a grounding ring on the non-drive end of a C-face motor?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A4:<\/strong>\u00a0 Absolutely.\u00a0 Sometimes you see C-face motors where there&rsquo;s enough room<img loading=\"lazy\" decoding=\"async\" class=\"alignright\" alt=\"c-face-baldo-e1598988859700\" height=\"175\" src=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/c-face-baldo-e1598988859700.jpeg\" width=\"256\"> at the drive end for a grounding ring.\u00a0 But you can always put a ring on at the opposite drive end.\u00a0 The one catch is for motors over 100 hp:\u00a0 They will have circulating currents, and we recommend an insulated bearing at the non-drive end.\u00a0 The grounding ring must always be at the opposite end from the insulated bearing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AEGIS Rings also come with a <a href=\"https:\/\/www.est-aegis.com\/product\/extended-warranty\/\" rel=\"noopener\" target=\"_blank\">2-year extended warranty<\/a> against bearing fluting damage. No other form of protection against VFD-caused bearing damage offers a warranty like this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To learn more about AEGIS shaft grounding and best practices for electrical bearing protection, <a href=\"https:\/\/www.est-aegis.com\/resources\/training\/\" rel=\"noopener\" target=\"_blank\">sign up for a training<\/a>. We offer monthly live training webinars, and &#8211; pandemic restrictions permitting &#8211; we can also visit your facility to review your exact application.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.est-aegis.com\/resources\/training\/\">Sign Up For Training<\/a><\/div>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.<\/p>\n","protected":false},"author":7,"featured_media":9604,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[1063],"tags":[],"class_list":["post-80","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qa-series"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.\" \/>\n\t<meta name=\"robots\" content=\"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n\t<meta name=\"author\" content=\"AEGIS\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"fr_FR\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Electro Static Technology\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Electrical Bearing Protection Q&amp;A Part 5\" \/>\n\t\t<meta property=\"og:description\" content=\"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"211\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-10-07T14:56:33+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-10-22T19:01:07+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Electrical Bearing Protection Q&amp;A Part 5\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@AEGIS_rings\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png\" \/>\n\t\t<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t\t<meta name=\"twitter:data1\" content=\"AEGIS\" \/>\n\t\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#article\",\"name\":\"Electrical Bearing Protection Q&A Part 5\",\"headline\":\"Electrical Bearing Protection Q&#038;A Part 5\",\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/tester-glam-300x211-1.png\",\"width\":300,\"height\":211,\"caption\":\"#image_title\"},\"datePublished\":\"2020-10-07T10:56:33-04:00\",\"dateModified\":\"2026-10-22T15:01:07-04:00\",\"inLanguage\":\"fr-FR\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#webpage\"},\"articleSection\":\"Q&amp;A Series, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"position\":2,\"name\":\"Q&amp;A Series\",\"item\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#listItem\",\"name\":\"Electrical Bearing Protection Q&#038;A Part 5\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#listItem\",\"position\":3,\"name\":\"Electrical Bearing Protection Q&#038;A Part 5\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/category\\\/qa-series\\\/#listItem\",\"name\":\"Q&amp;A Series\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\",\"name\":\"Electro Static Technology\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/logo-aegis-1.svg\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#organizationLogo\",\"width\":244,\"height\":73,\"caption\":\"aegis logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/AEGIS_rings\"],\"address\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#postaladdress\",\"@type\":\"PostalAddress\",\"streetAddress\":\"31 Winterbrook Road\",\"postalCode\":\"04256\",\"addressLocality\":\"Mechanic Falls\",\"addressRegion\":\"ME\",\"addressCountry\":\"US\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/\",\"name\":\"AEGIS\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"AEGIS\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#webpage\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/\",\"name\":\"Electrical Bearing Protection Q&A Part 5\",\"description\":\"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.\",\"inLanguage\":\"fr-FR\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/author\\\/aegis\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/wp-content\\\/uploads\\\/tester-glam-300x211-1.png\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#mainImage\",\"width\":300,\"height\":211,\"caption\":\"#image_title\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/blog\\\/electrical-bearing-protection-qa-part-5\\\/#mainImage\"},\"datePublished\":\"2020-10-07T10:56:33-04:00\",\"dateModified\":\"2026-10-22T15:01:07-04:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/\",\"name\":\"Electro Static Technology\",\"inLanguage\":\"fr-FR\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.est-aegis.com\\\/fr\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Electrical Bearing Protection Q&amp;A Part 5<\/title>\n\n","aioseo_head_json":{"title":"Electrical Bearing Protection Q&A Part 5","description":"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.","canonical_url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/","robots":"noindex, max-snippet:-1, max-image-preview:large, max-video-preview:-1","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#article","name":"Electrical Bearing Protection Q&A Part 5","headline":"Electrical Bearing Protection Q&#038;A Part 5","author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png","width":300,"height":211,"caption":"#image_title"},"datePublished":"2020-10-07T10:56:33-04:00","dateModified":"2026-10-22T15:01:07-04:00","inLanguage":"fr-FR","mainEntityOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#webpage"},"isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#webpage"},"articleSection":"Q&amp;A Series, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","position":1,"name":"Home","item":"https:\/\/www.est-aegis.com\/fr\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","position":2,"name":"Q&amp;A Series","item":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/","nextItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#listItem","name":"Electrical Bearing Protection Q&#038;A Part 5"},"previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#listItem","position":3,"name":"Electrical Bearing Protection Q&#038;A Part 5","previousItem":{"@type":"ListItem","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/#listItem","name":"Q&amp;A Series"}}]},{"@type":"Organization","@id":"https:\/\/www.est-aegis.com\/fr\/#organization","name":"Electro Static Technology","url":"https:\/\/www.est-aegis.com\/fr\/","logo":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/logo-aegis-1.svg","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#organizationLogo","width":244,"height":73,"caption":"aegis logo"},"image":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#organizationLogo"},"sameAs":["https:\/\/x.com\/AEGIS_rings"],"address":{"@id":"https:\/\/www.est-aegis.com\/fr\/#postaladdress","@type":"PostalAddress","streetAddress":"31 Winterbrook Road","postalCode":"04256","addressLocality":"Mechanic Falls","addressRegion":"ME","addressCountry":"US"}},{"@type":"Person","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author","url":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/","name":"AEGIS","image":{"@type":"ImageObject","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/8df5575541df78c551aa899db7bd2ee11bed27caea7dcd8c7695af230c7c1a04?s=96&d=mm&r=g","width":96,"height":96,"caption":"AEGIS"}},{"@type":"WebPage","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#webpage","url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/","name":"Electrical Bearing Protection Q&A Part 5","description":"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.","inLanguage":"fr-FR","isPartOf":{"@id":"https:\/\/www.est-aegis.com\/fr\/#website"},"breadcrumb":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#breadcrumblist"},"author":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"creator":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/author\/aegis\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png","@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#mainImage","width":300,"height":211,"caption":"#image_title"},"primaryImageOfPage":{"@id":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/#mainImage"},"datePublished":"2020-10-07T10:56:33-04:00","dateModified":"2026-10-22T15:01:07-04:00"},{"@type":"WebSite","@id":"https:\/\/www.est-aegis.com\/fr\/#website","url":"https:\/\/www.est-aegis.com\/fr\/","name":"Electro Static Technology","inLanguage":"fr-FR","publisher":{"@id":"https:\/\/www.est-aegis.com\/fr\/#organization"}}]},"og:locale":"fr_FR","og:site_name":"Electro Static Technology","og:type":"article","og:title":"Electrical Bearing Protection Q&amp;A Part 5","og:description":"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.","og:url":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/","og:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png","og:image:secure_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png","og:image:width":300,"og:image:height":211,"article:published_time":"2020-10-07T14:56:33+00:00","article:modified_time":"2026-10-22T19:01:07+00:00","twitter:card":"summary_large_image","twitter:site":"@AEGIS_rings","twitter:title":"Electrical Bearing Protection Q&amp;A Part 5","twitter:description":"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.","twitter:creator":"@AEGIS_rings","twitter:image":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png","twitter:label1":"\u00c9crit par","twitter:data1":"AEGIS","twitter:label2":"Estimation du temps de lecture","twitter:data2":"2 minutes"},"aioseo_meta_data":{"post_id":"80","title":"Electrical Bearing Protection Q&A Part 5","description":"Shaft grounding questions and answers on: Testing shaft voltage, shaft grounding equipment, different duty cycles, and C-face motors.","keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-11-04 18:58:30","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":null,"created":"2026-10-22 16:13:49","updated":"2026-11-16 20:18:33","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/\" title=\"Q&amp;A Series\">Q&amp;A Series<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\tElectrical Bearing Protection Q&amp;A Part 5\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/www.est-aegis.com\/fr\/"},{"label":"Q&amp;A Series","link":"https:\/\/www.est-aegis.com\/fr\/blog\/category\/qa-series\/"},{"label":"Electrical Bearing Protection Q&#038;A Part 5","link":"https:\/\/www.est-aegis.com\/fr\/blog\/electrical-bearing-protection-qa-part-5\/"}],"jetpack_featured_media_url":"https:\/\/www.est-aegis.com\/wp-content\/uploads\/tester-glam-300x211-1.png","_links":{"self":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/80","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/comments?post=80"}],"version-history":[{"count":3,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/80\/revisions"}],"predecessor-version":[{"id":10732,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/posts\/80\/revisions\/10732"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media\/9604"}],"wp:attachment":[{"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/media?parent=80"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/categories?post=80"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.est-aegis.com\/fr\/wp-json\/wp\/v2\/tags?post=80"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}